Page F6

 

 

 

 

Changing or adding 
new PIN codes/TAGS

 

 

Euro-MERiDIAN identifies each user 
by a different ‘User Number’. Eg 

‘John’ would be user 01 – ‘Jane’ 
would be user 02 etc. 

 

Now key in the ‘User Number’ 
whose PIN code/TAG you wish to 

add or change. 

 

Press ‘YES’ 

 

Key in the new 4,5 or 6 digit PIN 
code
 you require or  present the 

new Tag. 

 

To delete a code or Tag press ‘C’

 

Press ‘YES’ 

 

Euro-MERiDIAN will not allow you 

to programme in codes that are 
already in use by the system. 
Standard users can only edit their 
own code.  

Managers can only programme 
new users with access to the same 

areas as he/she has access. 

Note: ‘EN Grade 3’ 

alarm systems will 

only accept 5 or 6 

digit codes, or 

tags 

USER NUMBER  

               [02] 

ENTER USER CODE 

            [****] 

Summary of Contents for One

Page 1: ...Operator s Instructions Intruder Alarm System NE NEplus Euro MERiDIAN ...

Page 2: ...story Log F11 12 SMS Phonebook F13 Walk Testing Detectors F14 Testing your Sounder F15 SMS Messaging System F16 17 Dial Out Menu F18 Allow Engineer Menu F19 Block Remote Set F20 Perform Anti Code Reset F21 Service Codeholder Records G1 2 Note the specification of Euro MERiDIAN may vary between models and some facilities in the manual may not be available Check with your installer for full details ...

Page 3: ...the keypad becomes disabled for 90 seconds after 24 incorrect key presses or after 6 attempts to present invalid tags It will subsequently be disabled again after 7 further incorrect key presses or after another invalid tag is presented Once a correct code or tag has been registered the keypad is returned to normal operation Please note that Keypad design may differ from that shown ...

Page 4: ...ou need to call your alarm installation engineer The 10 digit numeric keypad is where you use your PIN code The A B C D keys help simplify use and will illuminate to highlight your choice of security cover or flash if there is a problem This is where you present your Tag MERiDIAN TIME MAINS FAIL ...

Page 5: ...own on the display To clear the display press the Yes key or the display will clear automatically after 3 minutes The Alarm lamp will flash after code entry if an alarm occurs The Tamper lamp will flash after code entry if the wiring or equipment is tampered with The Fault lamp will light after code entry to indicate if a technical fault occurs The Unset lamp will light for 5 seconds if the panel ...

Page 6: ...mity Tag or Card will set or unset your Alarm system with the minimum of fuss or complexity The Tag contains NO batteries and is completely maintenance free Just touch the Tag to the fascia below the logo to use The Keypad will BEEP to acknowledge the TAG ...

Page 7: ...Using the Keypad with your PIN Code or ...

Page 8: ...y Checks Before you set your system You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors Close Windows Close Doors Exclude Pets People ...

Page 9: ... which areas you set see page D2 Leave by agreed Exit Route Close and Lock the Final Exit Door Finally press the Push to Set button if fitted that is mounted externally by the final exit door Exit tone will cease Euro MERiDIAN is now SET SETTING 009 OFFICE Exit Timer If your exit is timed you will see the above screen If you use a Push to Set button or final door set you will see the screen below ...

Page 10: ...show the nature of the problem An appropriate A B C D key will flash to indicate within which area the fault exists The tone will cease after about 10 seconds Press the NO key The system will remain unset so you can resolve the problem For example you may have left a door open if so close the door Now commence the setting procedure again UNABLE TO SET BACK DOOR ...

Page 11: ...ed the exit tone continues to sound an interrupted tone beep beep beep You have probably left a protected door on the exit route open Return to the keypad and note the message on the display Stop the setting procedure with your PIN code or Tag Close the open door Now commence the setting procedure again see B2 EXIT VIA HALLWAY ...

Page 12: ...route and go straight to the keypad Entry tone will be sounding beep beep beep Key in your PIN code or present your Tag Entry tone will cease To indicate that the system has unset the unset lamp will illuminate for five seconds Euro MERiDIAN is now UNSET ENTRY 010 TIME ENTRY 020 TIME ...

Page 13: ...arm at night the Euro MERiDIAN s intelligent operating system will realise which level of security you require and will set only part of the system You will NOT need to press a Push to Set button if you set only part of a system If intelligent set is not installed on your system you may part set the system as described on Pages D1 D2 ...

Page 14: ...resent your Tag The appropriate A B C D keys will illuminate Exit tone will start Leave the protected area and retire to the un protected area eg upstairs Euro MERiDIAN will detect you have gone upstairs and set the appropriate areas accordingly After a preset time the exit tone will cease Euro MERiDIAN is now Part Set ...

Page 15: ...When Problems Arise Just Key in your PIN Code or ...

Page 16: ...ag The Alarm will stop sounding The display will indicate the problem Press the YES Key Euro MERiDIAN will advise you on any action that is needed If the Alert LED indication remains lit there is additional information available Enter your PIN or present your Tag to view Call Engineer Low Volts Alarm Silenced Low Volts ...

Page 17: ...larm Installation Company may permit you to reset the system without an engineer present You will be required to quote a 6 digit code by telephone advise them that the system is a Castle Euro MERiDIAN You will then be given a special code which will reset the system for that one occasion only Press NO Enter the anti code given to you by your installation company You alarm in now restored and ready...

Page 18: ...s in the same area or 1 confirmed alarm Keypad After 23 keypresses without entering a valid code keys are disabled for 90 seconds After reinstatement this will be repeated after each 7 keypresses until a valid code is entered Tag Reader or Tag at a keypad After 6 presentations of an invalid tag the reader will be disabled for 90 seconds After reinstatement this will be repeated for each invalid ta...

Page 19: ...Setting Individual Areas ...

Page 20: ...also give names to all four of the A B C D areas so that you can easily identify them For example A Reception or All Set B Warehouse Bedtime Set C Office Cat in Lounge D Storeroom Dog in Study In addition names can be given to the whole system ALL AREAS These will be displayed when setting the system MERiDIAN TIME MERiDIAN TIME SETTING ALL AREAS ...

Page 21: ... wish to set all the areas assigned to your code Tag simply select the areas you wish to Set by pressing the relevant A B C D key s To change your mind press the relevant A B C D key s again Press the Yes key to accept Setting areas will now be displayed with the corresponding area keys being lit Euro MERiDIAN will now Set the selected areas SETTING ALL AREAS SET AREAS ABCD ...

Page 22: ...tag is presented only area A will be unset If an A B tag is presented both A B will be unset An A B C tag will unset A B leaving C unset If entry timer is not running You will be asked if you wish to set any areas currently not set Press YES to do so or press NO to unset the system If there are NO areas set for which the code is valid the system will SET as described on page D2 Note Your alarm ins...

Page 23: ...at areas you would like to set or unset regardless of whether the entry timer is running or not providing you have a code valid for the relevant areas This function can only be enabled by your alarm installing company and will not be permitted if your system is designed to comply with clause 6 4 5 of DD243 2004 ...

Page 24: ...Page D3 Flexi Set This Page has been left Blank for Notes ...

Page 25: ...More Advanced Functions ...

Page 26: ...oor during the day Simply press the C key The display will show a C Now if the door opens you will be alerted by the chime tone To cancel the Chime function simply press C again Note This is only operative on detectors programmed for this purpose If multiple zones are programmed to permit this the sounder will not distinguish between them MERiDIAN TIME c MERiDIAN TIME MERiDIAN TIME ...

Page 27: ... display will ask if you wish to set with the fault To omit the fault Press YES or NO if you don t The system will then set as normal The fault will be omitted for this one arming period only NOTE iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii Only doors or windows already open can be omitted in this way The system may be programmed to be able to set with certain types of fault eg mains fail ...

Page 28: ... YES key When the OMIT INPUT menu is displayed Key in the number of the zone you wish to omit and press YES Always use a leading zero eg 02 is zone 2 On larger systems 002 is zone 2 If it has been accepted it will be displayed on the screen Repeat for any other zones that need to be omitted After 10 seconds Euro MERiDIAN will begin to set These zones will be omitted for this one period only OMIT I...

Page 29: ... reset Enter you PIN code or present your Tag Note ghgfiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii This facility is only available if it has been enabled by your alarm installer 2 Key PA and any duress codes programmed on the system by your engineer are not permitted to send a signal to the Alarm Receiving Centre under police regulations in England Wales or Northern Ireland MERiDIAN TIME ...

Page 30: ...This Page has been left Blank for Notes ...

Page 31: ... To enter Manager Menu press D and then key in your code or present your tag The screen will display any relevant information simply press No to move into Manager Menu We recommend that your system is fully disarmed to use Manager Menu functions ...

Page 32: ... Test CHC Communications see page F16 Dial Out Menu see page F18 Allow Engineer Menu see page F19 Block Remote Set see page F20 Download only in Engineer see page F21 Enter Anti Code see page F21 Exit Manager Menu see page F23 These features can also be accessed with a standard user code Pressing the NO key will take you from one Menu to the next as well as Escaping from within a menu Pressing the...

Page 33: ... code The first Menu choice asks you if you wish to Set Date Time If you wish to enter the menu press YES But if you wish to move on to other Manager Menu items press NO The USER MENU is similar to the manager menu with some choices unavailable see page F1 SET DATE TIME ...

Page 34: ...nter Year eg 06 2006 Press YES Enter Month Press YES Enter Day Press YES Enter Hours 24 hour clock Press YES Enter Minutes Press YES To go to the next menu press NO again Press YES Press NO to move to the next Menu SET DATE TIME YEAR 00 99 06 MONTH 1 12 08 DAY 1 31 12 HOURS 00 23 13 MINUTES 0 59 45 ...

Page 35: ...nd day alarm type can be omitted this way as set up by your alarm installing company Enter the zone number you wish to omit Press YES To reinstate zones simply key in the number again Press No when your selection is complete Noteiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii Zones omitted while UNSET will NOT be omitted when you SET the system See page E3 for more information on omitting zones Omit Zon...

Page 36: ...Press NO to programme the Master Manager Code Turn to the next page to continue to programme user codes Press YES Press NO to move to the next menu The Master Manager Code can only be changed by the Master Manager Turn to the next page to continue to programme the Master Manager Code CHANGE CODES Change User Codes Change Master Manager Code ...

Page 37: ...y in the new 4 5 or 6 digit PIN code you require or present the new Tag To delete a code or Tag press C Press YES Euro MERiDIAN will not allow you to programme in codes that are already in use by the system Standard users can only edit their own code Managers can only programme new users with access to the same areas as he she has access Note EN Grade 3 alarm systems will only accept 5 or 6 digit ...

Page 38: ... A B C D keys choose the areas you wish to be controlled by the code holder Managers may not give other users access to areas he himself cannot access Press YES Choose the limits you wish to place on the code holders actions Set Unset Set only Unset only choose None if the Tag is only for Access or Ward control Use B D keys to make your choice Press YES User Type User 0 User Areas A User Set Optio...

Page 39: ... the areas assigned without offering you the opportunity to choose For simplicity of use choose NO Make your choice with the B and D keys Press YES Flexi Set Yes 1 Systems installed to Grade 2 requirements must have 10 000 code differs Systems installed to Grade 3 requirements have must 100 000 code differs Tags have 2 8 thousand billion differs 1612 There are no disallowed codes Flexi Set Yes 1 F...

Page 40: ... move to next menu To assign a Tag to Access Control Readers or a Ward Reader Enter the Reader Numbers required Press YES To cancel a reader from the list Key in the number again Press YES When you have completed the list press NO again to go to the next menu Assign Codes to Readers Wards Access Wards Access 3 Stores Door ...

Page 41: ...y for space The A B C D keys on the keypad are used as follows A capital letters B moves cursor left C Clears Character creates a space D Cursor moves right eg to write Ben simply press the 2 key twice A key for capital D move cursor right 3 key twice D move cursor right 6 key twice Press Yes When you have finished and wish to go to the next menu press NO ...

Page 42: ...he next menu Press YES To advance through the logs Press D For added information Press C To move backward to previous events Press B To stop review Press NO To move to the next menu press NO again REVIEW LOG Panel Log Date Time EVENT Area Involved User Involved ...

Page 43: ... use a separate log is available dedicated to events using this function Follow the same procedure as described on page F11 but press NO to choose between PANEL LOG and ACCESS LOG Access Control is available if your panel is fitted with an MSX 76 or MSX 280 card ...

Page 44: ...YES Using the numeric keys type in the new telephone number do not leave any spaces You can move the cursor back with the B key and forward with the D key Use the C key to delete a character Press YES Select the next mobile telephone number you wish to change or Press NO to move to the next menu PHONEBOOK SMS Numbers 1 Mobile No 07 951_ SMS Numbers 1 ...

Page 45: ...ors waiting to be tested will scroll in the display Walk around the building and trigger all of the detectors The system will chime each time a detector responds When all detectors have been activated and are working the display will show Walk Test Completed To move to the next menu press No WALK TEST Walk Test Zone Front Door Walk Test Completed WALK TEST ...

Page 46: ...Page F15 Testing your Alarm Sounders Press YES Press NO to move to the next menu Press YES Siren will sound Strobe will flash Press NO to move to next menu SIREN TEST Testing Siren SIREN TEST ...

Page 47: ...utomatically via a premium rate number when the Euro MERiDIAN makes its regular authorisation and routing call to the messaging computer Should this call fail the display will show CHC Test Fail until the next time that the call is made successfully see next page for making test calls to the CHC This acts as a reminder that SMS Message signalling may not be operational but will not interfere with ...

Page 48: ...ke the test under the direction of an alarm engineer the test call will be via a premium rate number If your alarm panel is connected to an internal telephone network PABX system which requires a 9 for an outside line press YES otherwise press NO Once test is complete press YES TEST CHC COMMUNICATIONS Press Y if using PABX or N if not Testing to CHC Please Wait Test sent to CHC Test Complete ...

Page 49: ...e D key to select the operation you require Upload Logs View the system history on your PC where it can be searched and printed Diagnostics Sends electrical and diagnostic data to your PC where it can be printed if needed Press YES The Euro One panel does not have options to choose which PC it will dial it will automatically call PC 1 DIAL OUT MENU Select PC to dial 1 Select Operation Upload Logs ...

Page 50: ...nance visit or to correct a fault after an alarm he will require access to the programming of the system Press YES Use B D keys to make your choice Press YES After the engineer has finished on site you may return this setting to NO Page F19 Allow Engineer Menu ALLOW ENGINEER MENU Allow Engr Menu Yes 1 ...

Page 51: ...d so that your alarm installation company or company manager can set or unset the system remotely via PC Should you wish to block this access you can do so through this menu Press YES Make your choice with the B and D keys BLOCK REMOTE SET Block Remote Set No 0 ...

Page 52: ...menu Your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present Press YES You will be required to quote this 6 digit code by telephone advise them that the system is a Castle Euro MERiDIAN You will then be given a special code which will reset the system for that one occasion only Press YES After entering the correct anti code you may c...

Page 53: ...e Mobile Telephone Numbers page F13 Allow Engineer Access page F19 Inhibit omit Zones from the system page F3 Allow Remote Set page F20 To do so press D and enter your Manager PIN code or Tag Every user has access to the following programming options Change his own code page F5 Allow Remote Set page F20 Allow Engineer Access page F19 To do so press D and enter your User PIN code or Tag ...

Page 54: ...F23 Menu Exit To exit from Manager Menu and return to normal mode Press YES If you wish to select any of the Manager Menu items again press the NO key until your choice is displayed see F2 EXIT MANAGER MENU ...

Page 55: ...n installations designed to meet the requirements of Grade 2 Euro ONEPLUS and MSX upgraded panels meet the requirements of Grade 3 External set unset readers and access control readers meet the requirements of environmental class 4 Service Company Date of Installation Day Month Year Site Reference 24hr Service Number Tel Keyholders Name Tel Name Tel Panel Type Software Version Installed to Grade S...

Page 56: ...ning This information should be removed from the manual and stored in a secure location Photocopy this page if you have more users No Name Type Areas Attributes FlexiSet Access Reader 00 John Manager ABCD Set Unset NO 1 2 8 ...

Page 57: ...le companies whose operation is outside of the control or influence of Castle Care Tech Ltd Castle Control Panels have an embedded premium rate telephone number that is used to contact a Castle host computer prior to commissioning in order to download the SMSC details and appropriate call routing authorisation The control panel will continue to contact this CHC at regular intervals to verify the o...

Page 58: ...RINS1020 v1 Sept 2006 Your Alarm System is a Software Version ...

Reviews: