20
461308002 _006 12/2013
Some problems can be caused either as the results of simple maintenance operations or by incorrect selection
of settings. Prior to contacting a Service Centre please check the following chart.
PROBLEM
REMEDY
The appliance is not working
• Make sure the gas cock is open
• Check the plug is in
• Check that the knobs are set correctly for cooking and then repeat the
operations given in the handbook
• Check the electrical system safety switches (RCD). If there is failure in
the system call an electrician in.
The thermostat is not working
• Contact Service Centre..
The oven light does not switch on
• Make sure the lamp is irmly screwed in place
• Buy a lamp for high temperatures at one of our Service Centre and it
it following the instructions given in the paragraph «
REPLACING THE
OVEN LAMP»
..
Warning: Servicing should be carried out only by authorised personnel.
MAINTENANCE SCHEDULE
NO REGULAR MAINTENANCE IS REQUIRED
EXCEPT FOR CLEANING
INSTRUCTIONS FOR THE INSTALLER
TECHNICAL INFORMATION
The installations, conversions and maintenance
operations listed in this part must only be carried
out by authorised personnel. The manufacturer
cannot be held responsible for any damage to
persons or property resulting from an incorrect
installation of the appliance.
•
If the appliances is installed on a base ,
measures must be taken to prevent the
appliance from slipping from the base
•
The appliance is not intended to be operated by
means of an external timer or separate remote-
control system
.
•
The safety and automatic adjustment devices of the
appliances may, during its life, only be modiied by
the manufacturer or duly authorised supplier.
• This appliance shall be installed only by
authorised personnel and in accordance with
the manufacturer’s installation instructions, local
gas itting regulations, municipal building codes,
electrical wiring regulations, AS 5601 - Gas
Installations and any other statutory regulations.
• Fail
ure to install the appliance correctly could
invalidate any manufactures warranty and lead to
prosecution under the above quoted regulation.
• Before installation, make sure that local distribution
conditions (gas and electrical) are compatible with
the appliance’s adjustment. Refer to data label for
gas type.
• As it is not connected to a device for the evacuation
of the products of combustion, it must be installed in
accordance with current regulations and used in a
well ventilated location. Particular attention must be
paid to the regulations on ventilation.
TROUBLESHOOTING