background image

CONVERSIONS

8) U-LPG TO NATURAL GAS CONVERSION

PROCEDURE

Appliance models: Gas stainless steel hotplate

models:

1.   

Remove each burner cap and burner skirt.

2.  

Remove the U-LPG main injector with a 7

mm/VF  tube  spanner  and  replace  with  the

appropriate size Natural Gas injector for each

burner. The following injector sizes are required for

Natural Gas:

Burner

Main injector

Wok

1.76 mm

Rapid

1.55 mm

Semi Rapid

1.20 mm

Auxiliary

0.90 mm

Fish

1.55 mm

3.  

Shut off gas supply to the appliance.

4.  

Disconnect gas inlet pipe from the U-LPG Gas

test point inlet fitting.

5.  

Remove the U-LPG test point inlet fitting from

the appliance.

6.  

Fit the Natural Gas Regulator supplied in the

conversion kit.

7.  

Connect the gas supply to the Regulator.

8.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

9.  

Adjust the gas pressure to 1.00 kPa.

10.

Remove the control knob, with a thin shaft blade

screwdriver down the centre of each gas valve

shaft, screw the by-pass injector anti-clockwise.

Test the appliance on both high and low flame for

each burner. If the burner fails to remain alight or

the flame is not stable on the simmer setting, adjust

the by-pass screw, until flame is stable.

11.

If not already removed, remove the “Only for

use with U-LPG” label adhered to the bottom panel

near the gas connection.

9)  NATURAL  GAS  TO  UNIVERSAL 

LPG  CONVERSION  PROCEDURE

Appliance models: Gas stainless steel hotplate

models:

1.

Remove each burner cap and burner skirt.

2.  

Remove the Natural Gas main injector with a 7

mm/VF  tube  spanner  and  replace  with  the

appropriate size U-LPG main injector for each

burner. The following injector sizes are required for

U-LPG:

Burner

Main injector

Wok

0.94 mm

Rapid

0.91 mm

Semi Rapid

0.70 mm

Auxiliary

0.53 mm

Fish

0.91 mm

*1.00 mm main injector for models with enamelled

steel trivets.

3.  

Remove the control knob, with a thin shaft blade

screwdriver down the centre of each gas valve

shaft, screw the by-pass injector fully clockwise.

4.

Shut off gas supply to the appliance.

5.

Disconnect gas inlet pipe from the Natural Gas

Regulator.

6.

Remove the Natural Gas Regulator from the

appliance.

7.  

Fit the U-LPG test point inlet fitting supplied in

the conversion kit.

8.  

Connect the gas supply to the inlet fitting.

9.  

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

10. 

Adjust the gas pressure to 2.75 kPa.

11. 

Test the appliance on both high and low flame

for each burner and check the gas pressure. If the

burner fails to remain alight or the flame is not

stable on the simmer setting, adjust the by-pass

screw, until flame is stable.

12.

If not already removed, remove the “Only for

use with Natural Gas” label adhered to the bottom

panel near the gas connection.

10

Summary of Contents for EGZ90FCTSX

Page 1: ...op requires service please contact your local customer service centre or your nearest Eurostyle agent listed at the back of this booklet COD 04017HM 11 05 2012 Dear Customer Thank you for purchasing a...

Page 2: ...rivet 2 burners 8 Central U rapid burner Wok trivet 9 Central fish trivet 10 Burner 1 control knob 11 Burner 2 control knob 12 Burner 3 control knob left back 13 Burner 3 control knob right back 14 Bu...

Page 3: ...ion small flame fig 1 Always place a lid on the pans Burners Power ratings Pan in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 24 26 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 A...

Page 4: ...ouch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage resulting from improper incorrect or unreasonable use During and...

Page 5: ...Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To optimize the appear...

Page 6: ...st be a suitable non combustible material for a height of 150 mm for the entire length of the hob Any combustible construction above the hotplate must be at least 600 mm above the construction above t...

Page 7: ...be used and all connections tested for gas leaks The gas supply connection for the hose assembly must be accessible Natural Gas Natural Gas installations require the connection of a gas regulator at...

Page 8: ...the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspond...

Page 9: ...liance falls to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type a...

Page 10: ...bel adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 1 Remove each burner cap and burner ski...

Page 11: ...ad of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the autho...

Page 12: ...p is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the ta...

Page 13: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Page 14: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Page 15: ...15...

Page 16: ...16...

Reviews: