I N S T A L L A T I O N S   I N S T R U C T I O N S

 IMPORTANT NOTICE TO THE INSTALLER
 GAS CONNECTION

The appliance shall be installed by an authorized person in

accordance with the manufacturer’s installation instructions,

relevant local fitting regulations, municipal building regulations,

the AS5601 ( AG601 ) - Gas Istallation . For gas burning appliances

and equipment and other relevant statutory code band regulations.

If  you  have  some  doubts,  please  contact  the  authorities  for

confirmation concerning the characteristics of the gas and electricity

output.

This appliance can be connected with rigid pipe as specified in

AS5601 table 3.1 or with a Flexible Hose which complies with

AS/ANZ 1869 (AGA Approved), 10mm ID, class B or D, no more

that 1.2m long and in accordance with AS5601. 

Ensure that the

Hose does not contact the hot surfaces of the hotplate, oven,

dishwasher  or  other  appliance  that  may  be  installed

underneath or next to the hotplate. The Hose should not be

subjected to abrasion, kinking or permanent deformation and

should be able to be inspected along its entire length. Unions

compatible  with  the  hose  fittings  must  be  used  and

connections tested for gas leaks. The supply connection point

shall be accessible with the appliance installed.

The appliance is generally preset for natural gas (so no other

adjustment is necessary) and equipped with a regulator with

pressure test point. Ensure that all foreign matter has been cleared

from the gas supply line and also purge all air from the gas system.

Connect to regulator, tighten and check the installation to ensure

no gas leaks occur. Check gas pressure, a duplicate label is

supplied and adhered to the front of this instruction manual, note

the correct setting from the data plate sealed on the lower side

This appliance from the factory suitable for NATURAL gas but, if

necessary, can be adjusted for U-LPG or TLP gas by a competent

licensed person.

5 BURNER UNIT
 DIMENSIONS

Overall Height above work surface ...................................45 mm

Width .........................................................................680 mm

Depth.........................................................................510 mm

Minimum space above hotplate ......................................600 mm

CONNECTIONS

Gas..............................................................RC 1/2 (1/2" B.S.P.)

Electric  ......................1 mm

2

 3 core cable (3 amp fuse required)

Should conform to local gas authority requirements.

Also refer to rangehood manufacturers recommendations.

GAS HOT PLATE

U S E R S   I N S T R U C T I O N S

To light the burner, turn the appropriate knob anticlockwise to the

low position (marked with a small flame symbol      ) and depress

the ignition button and release. If burner does not ignite repeat

the procedure. To adjust the burner to the full-on position, turn the

control knob clockwise to the appropriate setting (marked with a

large flame symbol      ).
Where this appliance is installed in marine craft or in caravans,

it shall 

NOT

 be used as a space heater".

To turn the burner OFF, turn the control knob clockwise to the

OFF setting (marked with a dot    ).

B

A

A

B

C

Fig. 1

A

-Burner cap

B

-Lighting plug

C

-Triple flame cap

APPLIANCES WITH SAFETY VALVE

Follow the same procedure described above to ignite the burners.

In this case, however, once you have turned the knob to the open

setting, hold it pressed in for 10 seconds. If for any areason the

burner flame goes out, the safety valve automatically shuts off the

gas supply to the burner in question.

It is recommended that pans suitable to the size of the burner

should de used as follows:

Burner                                          minimum              maxmum
                                                         diameter                diameter

Large (rapid)                             180mm               230mm
Medium (semi-rapid)                   120mm               200mm
Small (Auxiliary)                         80mm              160mm
Triple Flame                           220mm              260mm

Always use pans with all flat base diameter, which are well balanced

and stable in use, a pan which overhangs the hotplate should not

be used. Avoid using old, misshapen pans, or pans which are

unstable when placed on a flat surface. Do not use “split pans”

of the case. 5 burner models: "burner pressure is to be set at 1

kpa with middle front and right front burners operating at full rate.

Apply a manometer to the test nipple and reset the regulator if

necessary.Do not forget to replace the test nipple screw and to

leave the instructions book with the user.

For the adjustments to TLP or U-LPG gas, please operate as

specified  in  the  paragraph  GAS  CONVERSION  AND

ADJUSTMENT (Page. 8).

Important: several parts are protected with a special anti-scratch

film. Please remove it before use.

Dual triple flame version

no gas flow

maximum gas flow from central burner

minimum gas flow from central burner

maximum  gas  flow  from  outer  and  central  burners
simultaneously

minimum  gas  flow  from  outer  and  central  burners
simultaneously