I N S T A L L A T I O N S I N S T R U C T I O N S
IMPORTANT NOTICE TO THE INSTALLER
GAS CONNECTION
The appliance shall be installed by an authorized person in
accordance with the manufacturers installation instructions,
relevant local fitting regulations, municipal building regulations,
the AS5601 ( AG601 ) - Gas Istallation . For gas burning appliances
and equipment and other relevant statutory code band regulations.
If you have some doubts, please contact the authorities for
confirmation concerning the characteristics of the gas and electricity
output.
This appliance can be connected with rigid pipe as specified in
AS5601 table 3.1 or with a Flexible Hose which complies with
AS/ANZ 1869 (AGA Approved), 10mm ID, class B or D, no more
that 1.2m long and in accordance with AS5601.
Ensure that the
Hose does not contact the hot surfaces of the hotplate, oven,
dishwasher or other appliance that may be installed
underneath or next to the hotplate. The Hose should not be
subjected to abrasion, kinking or permanent deformation and
should be able to be inspected along its entire length. Unions
compatible with the hose fittings must be used and
connections tested for gas leaks. The supply connection point
shall be accessible with the appliance installed.
The appliance is generally preset for natural gas (so no other
adjustment is necessary) and equipped with a regulator with
pressure test point. Ensure that all foreign matter has been cleared
from the gas supply line and also purge all air from the gas system.
Connect to regulator, tighten and check the installation to ensure
no gas leaks occur. Check gas pressure, a duplicate label is
supplied and adhered to the front of this instruction manual, note
the correct setting from the data plate sealed on the lower side
This appliance from the factory suitable for NATURAL gas but, if
necessary, can be adjusted for U-LPG or TLP gas by a competent
licensed person.
5 BURNER UNIT
DIMENSIONS
Overall Height above work surface ...................................45 mm
Width .........................................................................680 mm
Depth.........................................................................510 mm
Minimum space above hotplate ......................................600 mm
CONNECTIONS
Gas..............................................................RC 1/2 (1/2" B.S.P.)
Electric ......................1 mm
2
3 core cable (3 amp fuse required)
Should conform to local gas authority requirements.
Also refer to rangehood manufacturers recommendations.
GAS HOT PLATE
U S E R S I N S T R U C T I O N S
To light the burner, turn the appropriate knob anticlockwise to the
low position (marked with a small flame symbol ) and depress
the ignition button and release. If burner does not ignite repeat
the procedure. To adjust the burner to the full-on position, turn the
control knob clockwise to the appropriate setting (marked with a
large flame symbol ).
Where this appliance is installed in marine craft or in caravans,
it shall
NOT
be used as a space heater".
To turn the burner OFF, turn the control knob clockwise to the
OFF setting (marked with a dot ).
B
A
A
B
C
Fig. 1
A
-Burner cap
B
-Lighting plug
C
-Triple flame cap
APPLIANCES WITH SAFETY VALVE
Follow the same procedure described above to ignite the burners.
In this case, however, once you have turned the knob to the open
setting, hold it pressed in for 10 seconds. If for any areason the
burner flame goes out, the safety valve automatically shuts off the
gas supply to the burner in question.
It is recommended that pans suitable to the size of the burner
should de used as follows:
Burner minimum maxmum
diameter diameter
Large (rapid) 180mm 230mm
Medium (semi-rapid) 120mm 200mm
Small (Auxiliary) 80mm 160mm
Triple Flame 220mm 260mm
Always use pans with all flat base diameter, which are well balanced
and stable in use, a pan which overhangs the hotplate should not
be used. Avoid using old, misshapen pans, or pans which are
unstable when placed on a flat surface. Do not use split pans
of the case. 5 burner models: "burner pressure is to be set at 1
kpa with middle front and right front burners operating at full rate.
Apply a manometer to the test nipple and reset the regulator if
necessary.Do not forget to replace the test nipple screw and to
leave the instructions book with the user.
For the adjustments to TLP or U-LPG gas, please operate as
specified in the paragraph GAS CONVERSION AND
ADJUSTMENT (Page. 8).
Important: several parts are protected with a special anti-scratch
film. Please remove it before use.
Dual triple flame version
no gas flow
maximum gas flow from central burner
minimum gas flow from central burner
maximum gas flow from outer and central burners
simultaneously
minimum gas flow from outer and central burners
simultaneously