Euro Towers 750K Instructions For Use Manual Download Page 11

Maximum distance 

between platforms 

shall not exceed 

2.25m except the 

distance to the first 

platform max 3.40m

Do not bridge be-

tween towers or oth-

er structures Please 

contact Euro Towers 

for information on the 

correct equipment for 

Bridging Towers

Maximum inclination 

for 

movement

. Note 

the maximum angle 

allowed is defined by 

the manufacturer

Do not build, disman-

tle or attempt to work 

on an access tower if 

the wind speed

exceeds 17MPH

Maximum inclination 

for movement. Note 

the maximum angle 

allowed is defined by 

the manufacturer

Do not stand on an 

unguarded platform

Do not lift the tower 

with mechanical 

equipment

Do not use the 

tower for access 

and egress to other 

structures

Do not suspend the 

tower

Do not lift heavy ob-

jects from the tower

Do not move the 

tower with people or 

materials on it

Do not use ladders,box-

es or other objects to 

gain extra height

Do not climb the outside of the tower

DISMANTLE TOWER IN REVERSE EXCEPT WHEN DISMANTLING THE HANDRAILS 

Unclip 4 x Horizontal 

braces from the far end of 

the trapdoor platform.

From a seated position remove 

4 x guardrails making sure you 

never stand on an unprotected 

platform.

From a seated position descend 

down the tower to the next 

platform or ground. Ensure you 

always have collective protec-

tion around you when standing 

on any platform. 

Summary of Contents for 750K

Page 1: ...G LOAD 250KG Trapdoor Platform Diagonal Brace 2M White Green Red 2 5M White Green Yellow 3M White Green Blue Castor Adjustable Leg 232 SINGLE WIDTH TOWER 3T THROUGH THE TRAPDOOR METHOD AUGUST 21 Side...

Page 2: ...ould be replaced and sent for repair or scrap 17 Inspect all tube on frames stabilisers and braces for dents cuts and holes damaged equipment should be isolated tagged and removed from use Check all j...

Page 3: ...r stand on an unprotected platform guardrails must be in place 44 Consider measures to secure the tower when left unattended Stability Moving 45 Ensure the Tower is level and the adjustable legs are e...

Page 4: ...tight and push from at or near the base by manu al effort only never use mechanical means Recheck level and reposition stabilizers before use ALTERNATIVE FRAMES CONFIGURATION For example where 2 x 8 r...

Page 5: ...0m 1 88m 5 13m 1 41 4 66m 7 91m PPE REQUIRED Hard Hat Safety Gloves Safety Boots Shoes Hi Viz Vest Jacket TOOLS REQUIRED Spirit Level...

Page 6: ...from 1st to 6th rungs in a alternate patter and install 1 additional diagonal brace from the 6th to 10th rung See figure 3 6 6 Rung Base Set Up For Platform Heights 1 88m 3 73m 5 59m 7 45m When using...

Page 7: ...Remove your temporary board and guardrail braces Then reposition your diagonal brace to 1st to 3rd and add an additional brace on the al ternative side Finally add an additional diagonal brace from 3r...

Page 8: ...es above first rung Horizontal braces fit on from the inside of the tower facing outwards 5 Fit 1 plain platform on the appropriate rung See base build for desired platform height Level your tower by...

Page 9: ...diagonal braces from 3rd to 1st rung 9 Fit 4 horizontal braces directly above platform to create your collective protection Hooks facing outwards on frame uprights 10 Fit 4 stabilisers at earliest op...

Page 10: ...s illustrated using all components Platforms inserted every 2m complete with handrails Braces run in a continuous pattern on opposite sides 15 For your working platform fit trapdoor on the 6th rung do...

Page 11: ...unguarded platform Do not lift the tower with mechanical equipment Do not use the tower for access and egress to other structures Do not suspend the tower Do not lift heavy ob jects from the tower Do...

Page 12: ......

Reviews: