Maximum distance
between platforms
shall not exceed
2.25m except the
distance to the first
platform max 3.40m
Do not bridge be-
tween towers or oth-
er structures Please
contact Euro Towers
for information on the
correct equipment for
Bridging Towers
Maximum inclination
for
movement
. Note
the maximum angle
allowed is defined by
the manufacturer
Do not build, disman-
tle or attempt to work
on an access tower if
the wind speed
exceeds 17MPH
Maximum inclination
for movement. Note
the maximum angle
allowed is defined by
the manufacturer
Do not stand on an
unguarded platform
Do not lift the tower
with mechanical
equipment
Do not use the
tower for access
and egress to other
structures
Do not suspend the
tower
Do not lift heavy ob-
jects from the tower
Do not move the
tower with people or
materials on it
Do not use ladders,box-
es or other objects to
gain extra height
Do not climb the outside of the tower
DISMANTLE TOWER IN REVERSE EXCEPT WHEN DISMANTLING THE HANDRAILS
Unclip 4 x Horizontal
braces from the far end of
the trapdoor platform.
From a seated position remove
4 x guardrails making sure you
never stand on an unprotected
platform.
From a seated position descend
down the tower to the next
platform or ground. Ensure you
always have collective protec-
tion around you when standing
on any platform.