71
Wiring diagram
Connecting an isolated output to a TTL receiver using the receiver's V
CC
supply
See also:
in the hardware manual for I/O connectors pin assignments.
1.
Connect OUT+ to TTL V
CC
. Nominally, V
CC
should be 3.3 V or 5 V.
2.
Connect OUT- to the TTL input.
3.
Pull-down OUT- with a resistor (R) of 180 ohm 1/8 W (or another resistor value that suits the
circuit requirements).
TIP
As good practice, it is recommended to shield the whole set of wires, using a
shielded cable. Shielding improve EMI protection against external
interferences (immunity) and avoid unwanted EM emissions. The shield
should be connected to the devices (PC, cameras, and systems components)
chassis and should be separated from the digital GND line.
Static levels compatibility
The following tables show that the voltage levels are well compatible and that they remains
acceptable voltage margins for both TTL and LVTTL applications.
Coaxlink
Hardware Manual
Summary of Contents for Coaxlink 1629
Page 4: ...4 1 About This Document 1 1 Document Scope 5 Coaxlink Hardware Manual ...
Page 7: ...7 2 1 Board and Bracket Layouts Coaxlink Hardware Manual ...
Page 9: ...9 2 2 Connectors Coaxlink Hardware Manual ...
Page 17: ...17 2 3 LEDs Coaxlink Hardware Manual ...
Page 33: ...33 3 3 Power Distribution Schemes Coaxlink Hardware Manual ...
Page 64: ...64 6 Appendix Appendix to Coaxlink cards hardware manual Coaxlink Hardware Manual ...