11
EN
6.5
FILTER HOLDER FORK ADJUSTMENT
Insert the filter holder fork (6) into its seat
(Fig. 6)
.
With a screwdriver, loosen the fixing screw of the filter holder fork
(6)
.
Do not loosen the screw completely.
/LIWRUORZHUWKHIRUNWRDGMXVWLWDFFRUGLQJWRWKHILOWHUKROGHUGLPHQVLRQV
(Fig. 7)
.
2QFHKDYLQJIRXQGWKHFRUUHFWSRVLWLRQWLJKWHQWKHIRUNIL[LQJVFUHZ
(6)
.
7KHIRUNLVVXLWDEOHIRUDQ\NLQGRIILOWHUKROGHUDYDLODEOHRQWKHPDUNHW
6.6
MACHINE PROGRAMMING
(PERFETTO - SPECIALITA' - MAGNIFICO)
6.6.1
TURNING THE MACHINE ON
When starting the machine for the first time, the appliance has the factory default
settings. In the subsequent starts, it keeps the settings preceding the last turning off.
When starting, the display loads the firmware and gets ready for dispensing.
6.6.2
DOSE DISPENSING AND ADJUSTMENT (DISPLAY)
By pressing the button of one dose
(16)
or double dose
(17)
, the dose to be
dispensed is selected (the buttons goes on).
:LWKDVLQJOHSUHVVXUHTXLFNRIWKHJULQGLQJVWDUWEXWWRQ
(5)
, the coffee dispensing and
the countdown to zero are activated.
:KHQWKHGLVSHQVLQJLVFRPSOHWHWKHJULQGLQJWLPHJRHVEDFNWRWKHYDOXHVHW
7KHFRXQWHURIVLQJOHRUGRXEOHGRVHVLVLQFUHDVHGE\
6HOHFWWKHVLQJOH
(16)
or double dose
(17)
and press the buttons
(14)
and
(15)
to increase or reduce the dispensing time of the selected dose (the time is
shown in seconds on the display).
,I WKH EXWWRQ
(14)
or
(15)
is kept pressed for some seconds, the time is
increased or reduced according to the pressure time.
To pause the automatic dispensing before the grinding time has elapsed, press the
grinding start button (5) with the filter holder:
3UHVVWKHEXWWRQDJDLQWRUHVWDUWWKHGLVSHQVLQJIRUWKHUHPDLQLQJWLPH
.HHSSUHVVHGWKHEXWWRQRIWKHVHOHFWHGGRVHEOLQNLQJWRVWRSGLVSHQVLQJ7KH
grinding time goes back to the value set.
6.6.3
CONTINUOUS DISPENSING
Press the single dose
(16)
and double dose
(17)
buttons at the same time to
access this mode. The symbol
(13)
appears on the display.
Press the grinding start button
(5)
to enable the continuous dispensing and press it once
more to stop. The continuous dispensing lasts up to max. 60 seconds.
To exit the continuous dispensing mode, keep pressed the single dose
(16)
or the
double dose
(17)
button for some seconds.