Euphonix Modular I/O Configuration Guide
Product Data Sheets
60
2/3
Technical Specifications
sync interface
internal sync:
switchable 44.1, 48, 96kHz,
external sync:
VIDEO connector:
BNC, 75 Ohm, coaxial
level:
0,5 ... 1 Vpp (BB/CS)
+/-0,3V
(Tri-Level)
input format:
PAL / NTSC / HDTV
rates: 1080i/50/59.94/60
720p/50/59.94/60
1080p/23.98/24/25/29.97/30/50/59.94/60
WCLK connector:
BNC, 75 Ohm, coaxial
level: TTL-level
AES
connector:
BNC, 75 Ohm, coaxial
Level:
0,5 ... 5 Vpp
general
backplane connector: ref. to DIN41612, 64pin, a+b, male
power supply:
+5V DC
consumption:
approx. 300 mA
dimensions:
3RU, 4HP, 175mm depth
weight:
~200g
Installation
Module exchange
When swapping out the SY982, the frame must be powered off if there is no
redundant sync module fitted. Without stable clock some interface modules can
fall into irregular condition which can damage parts of the circuits
SY983 Sync
Summary of Contents for Modular I/O
Page 2: ......