15
Sync in (BNC), Word Clock out (BNC), ~300 mA, 4HP,
~200g.
1.2.5 SY983 Sync
General Description
The SY983 contains an internal clock and can lock to
external AES Sync, Word Clock, Video signal, or Tri-Level
Sync. Internal sample rates are 44.1k, 48k, 88.2k, and 96k.
The module features a sync redundancy mode which allows
two modules, designated master and slave, to be fitted into a
rack. If the master loses sync, the slave automatically takes
over. SY983 Sync modules must be fitted into any of the
four reserved slots on the rear-plane. On-board switches
are used for certain settings including device ID. Web-
browser interface via FC972 Remote provides access to
module status and settings.
Note: The SY983 Sync module should only be
removed from a frame after the frame has been
powered down. Possible damage may occur to some
I/O modules if the master sync source is removed
from a live frame.
Connections, Power Consumption, Width, Weight
Sync in (BNC), Word Clock out (BNC), ~300 mA, 4HP,
~200g.
1.2.6 FC972 Remote
General Description
The FC972 acts as a TCP/IP interface to the frame’s internal
communications buss. Frames with externally configured
modules (remote preamps, 8-ch embedder/de-embedder,
SY983 Sync) must have an FC972 Remote fitted.
Configuration of this module via serial and/or web browser
interface may be necessary. See the manufacturer’s data
sheet for details.
Connections, Power Consumption, Width, Weight