background image

Euphonix MADI Converters Operation Manual

 

MI715/MO705 Converters Features

9

Ϯ͘ϰ

MI715

 

Rear

 

Panel

MA715

 

Rear

 

Panel

Input

 

Voltage

 

Selector:

 

This

 

red

 

switch

 

allows

 

the

 

unit

 

to

 

operate

 

in

 

either

 

110/115

 

VAC

 

or

 

220/230/240

 

VAC

 

environments.

 

A

 

fuse

 

must

 

also

 

be

 

changed

 

for

 

220/230/240

 

VAC

 

operation

 

(see

 

page

 

5

).

 

Units

 

are

 

shipped

 

set

 

and

 

fused

 

for

 

110/115

 

VAC.

 

Power

 

Connector

 

(IEC)

 

and

 

Fuse

 

Tray:

 

The

 

IEC

 

power

 

connector

 

accepts

 

standard

 

IEC

 

power

 

cords.

 

The

 

fuse

 

tray

 

contains

 

both

 

the

 

active

 

fuse

 

and

 

a

 

spare

 

fuse

 

for

 

220/230/

240

 

VAC

 

operation.

 

See

 

page

 

6

 

for

 

instructions

 

on

 

how

 

to

 

change

 

the

 

fuse

 

for

 

220/

230/240

 

VAC

 

operation.

 

Analog

 

Inputs

 

(female

 

XLR):

 

8

 

balanced,

 

analog

 

inputs

 

on

 

XLR

 

connectors.

 

Input

 

sen

sitivity

 

is

 

set

 

from

 

the

 

front

 

panel.

AES/EBU

 

Digital

 

Input

 

(female

 

XLR):

 

8

 

Stereo

 

AES/EBU

 

digital

 

input

 

on

 

XLR

 

connectors

 

Parallel

 

AES/EBU

 

Digital

 

Inputs

 

(female

 

DB25):

 

Two

 

8

channel

 

digital

 

connectors

 

function

 

in

 

parallel

 

with

 

XLR

 

digital

 

inputs,

 

and

 

should

 

not

 

be

 

used

 

simultaneously

 

AES

 

Sync

 

In

 

(female

 

XLR):

 

Master

 

clock

 

input

 

for

 

the

 

converter

 

when

 

using

 

AES

 

as

 

Sam

ple

 

Rate

 

Source.

AES

 

Sync

 

Thru

 

(male

 

XLR):

 

Outputs

 

the

 

same

 

signal

 

connected

 

to

 

AES

 

Sync

 

In.

Word

 

In

 

(BNC):

 

Master

 

clock

 

input

 

for

 

the

 

converter

 

when

 

using

 

Word

 

Clock

 

as

 

Sam

ple

 

Rate

 

Source.

Word

 

Out

 

(BNC):

 

Outputs

 

a

 

Word

 

clock

 

signal

 

synchronized

 

to

 

the

 

Sample

 

Rate

 

Source.

 

In

 

the

 

presence

 

of

 

an

 

external

 

Word

 

clock

 

input,

 

this

 

connector

 

provides

 

a

 

regenerated

 

version

 

of

 

that

 

input

 

signal.

 

Without

 

an

 

external

 

sample

 

rate

 

source,

 

this

 

connector

 

outputs

 

the

 

internally

 

generated

 

clock

 

signal.

Summary of Contents for MADI MI715

Page 1: ...ES to MADI MO705 MADI to Analog AES Document Revision 1 1 Release Date Jan 2009 Part Number 840 10631 01 Euphonix Inc 220 Portage Ave Palo Alto California 94306 Phone 650 855 0400 Fax 650 855 0410 e mail info euphonix com Web http www euphonix com ...

Page 2: ...ce or obligation System 5 S5 Max Air PatchNet eMix EuCon R 1 Audio Deck Studio Hub are trademarks of Euphonix Inc 2002 Euphonix Inc All rights reserved worldwide No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means without written permission from Euphonix Inc ...

Page 3: ...2 Power On Sequence 5 1 3 Safety and Precautions 5 1 3 1 220 230 240 VAC Operation 5 Chapter 2 MI715 and MO705 Converters 7 2 1 Features 7 2 2 Applications 7 2 3 MI715 MO705 Front Panel 8 2 4 MI715 Rear Panel 9 2 5 MO705 Rear Panel 11 2 6 Synchroniztion 12 2 6 1 MI715 12 2 6 2 MO705 12 2 7 Specifications 13 ...

Page 4: ... the input s complete dynamic range Each main AES EBU input is automatically evaluat edforsample rateconversion The incoming sample rate is compared with the internal rate If they are the same no conversion occurs If the rates differ sample rate con version is activated and persists until a new input is applied or the internal sample rate changes The sample rate conversion range is 32 56 kHz In ad...

Page 5: ...AC settings The converters preserve their signal quality using linear power supplies that must be manually switched between 115 and 230 VAC The units are shipped set for 115 VAC Move the red two position switch near the power entry module of the converters to the 230 VAC position down for 220 230 240 VAC operation Each unit uses a 0 630 A fuse for 115 VAC operation To operate at 220 230 or 240 VAC...

Page 6: ...it is the responsibility of the user to select an approved power cord with proper construction material current capacity flexibility and strength characteristics Cooling We strongly recommend providing adequate ventilation to the converters particular ly when installed in a rack The MI715 and MO705 converters in particular should have space left above and below every two units so heat can properly...

Page 7: ...k external sync inputs on both units provide synchronization to digital systems Sample Rate Source and Sample Rate are automatically sensed by both units Supported sample rates include 44 1 48 88 2 and 96 kHz In addition pull up and pull down rates for the standard sample rates as well as custom sample rates are available Ϯ Ϯ Applications In addition to their standard use in a Euphonix digital sys...

Page 8: ...nsed or manually selected If an external source is not detected the MI715 reverts to Internal sync the MO705 mutes its outputs If a manually selected source is not present the Sample Rate Source indicator blinks AES Sample Rate locked to AES Input Word Sample Rate locked to Word Clock Input Internal MI715 only Sample Rate locked to its own internal crystal MADI MO705 only Sample Rate locked to MAD...

Page 9: ...s on XLR connectors Input sen sitivity is set from the front panel AES EBU Digital Input female XLR 8 Stereo AES EBU digital input on XLR connectors Parallel AES EBU Digital Inputs female DB25 Two 8 channel digital connectors function in parallel with XLR digital inputs and should not be used simultaneously AES Sync In female XLR Master clock input for the converter when using AES as Sam ple Rate ...

Page 10: ...Euphonix MADI Converters Operation Manual MI715 MO705 Converters Features 10 MADI Out BNC Outputs the digital audio signal 1 8 Analog inputs 9 24 AES inputs ...

Page 11: ...R 8 Stereo AES EBU digital outputs on one XLR connector Parallel AES EBU Digital Outputs female DB25 Two 8 channel digital connectors function in parallel with XLR digital outputs and the two outputs should not be used simultaneously See Figure 3 5 on page 33 for pinout diagram AES Sync In female XLR Master clock input for the converter when using AES as the Sample Rate Source AES Sync Thru male X...

Page 12: ...its internal clock derived from on board volt age controlled crystal The default internal Sample Rate of the MI715 is 48 kHz This default internal rate can be overridden with the Sample Rate button on the front panel of the MI715 directly below the Sample Rate LEDs to 44 1 48 or 96 kHz Ϯ ϲ 2 MO705 The MO705 detects Sample Rate and Sample Rate Source like the MI715 with the following two difference...

Page 13: ...y 12 to 5 Audio Inputs 8 analog 16 AES 8 AES Pairs Analog Inputs 1 8 Electronically balanced XLR 20 k input impedance Level for 0 dBFS Adjustable between 12 and 26 dBu in 2 dB steps Signal to Noise Ratio 105 dB unweighted THD 0 0005 Frequency Response 1 kHz 4 dBu 0 25 dB 20 Hz 20 kHz 48 kHz 2 5 dB 20 Hz 40 kHz 96 kHz CMRR 50 dB 20 Hz 20 kHz Crosstalk 110 dB 1 kHz 100dB 20 Hz 20 kHz Group Delay 41 ...

Page 14: ...s 1 8 Electronically balanced XLR 200 output impedance Level for 0 dBFS Adjustable between 12 and 26 dBu in 2 dB steps Signal to Noise Ratio 101 dB unweighted THD 0 0003 Frequency Response 1 kHz 4 dBu 0 25 dB 20 Hz 20 kHz 48 kHz 2 5 dB 20 Hz 40 kHz 96 kHz CMRR 50 dB 20 Hz 20 kHz Crosstalk 110 dB 1 kHz 100 dB 20 Hz 20 kHz Group Delay 28 2 Fs 588 s 48 kHz AES Outputs 9 24 AES on XLR transformer isol...

Page 15: ... MO705 Converters Features 15 IM715 MO705 Technical Specifications Power Requirements 110 115 VAC or 220 230 240 VAC 50 or 60 Hz Power Consumption 50 W Temperature of Operation 5 35 C Dimensions Height 3 5 in Width 19 in Depth 18 25 in Weight 17 lb ...

Page 16: ... Manual written by Jay Spears and Eddie Jones Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy ...

Page 17: ... s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third groundingprong Thewiderbladeorthethirdprongareprovidedforyour...

Page 18: ... supply cord shall remain readily operable 19 This unit is provided with a power supply cord set suitable for 120V AC input only for U S A and Canada For other than U S A and Canada a qualified person must provide for use with this unit an appropriate approved power supply cord set which is in compliance with the end use country requirements and has a minimum cross sectional area of 1 0mm2 20 For ...

Reviews: