background image

5

Operating Instructions

Safety Switch NM..WO/RB

Inspection and service

 WARNING

Danger of severe injuries due to the loss of the 

safety function.

 

f

If damage or wear is found, the complete switch 

must be replaced. Replacement of individual 

parts or assemblies is not permitted.

 

f

Check the device for proper function at regular 

intervals and after every fault. For informa-

tion about possible time intervals, refer to 

EN ISO 14119:2013, section 8.2.

Inspection of the following is necessary to ensure 

trouble-free long-term operation:

 

f

correct switching function

 

f

secure mounting of all components

 

f

damage, heavy contamination, dirt and wear

 

f

sealing of cable entry

 

f

loose cable connections or plug connectors.

Information: The year of manufacture can be seen 

in the bottom, right corner of the type label.

Exclusion of liability and warranty

In case of failure to comply with the conditions for 

correct use stated above, or if the safety instruc-

tions are not followed, or if any servicing is not 

performed as required, liability will be excluded and 

the warranty void.

Notes about 

For use and applications as per the requirements of 

, a class 2 power supply according to UL1310 

must be used. 

EU declaration of conformity

The declaration of conformity is part of the oper-

ating instructions, and it is included as a separate 

sheet with the unit. 
The original EU declaration of conformity can also 

be found at: www.euchner.com

Service

If service support is required, please contact:
EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

D-70771 Leinfelden-Echterdingen
Service telephone:

+49 711 7597-500
Fax:

+49 711 753316
E-mail:

[email protected]
Internet:

www.euchner.de

Figure 3:  Switching elements and switching func-

tions

21

13

21

31

11

21

31

31
21

13

21

22

14

22

32

12

22

32

32
22

14

22

21

31
21

13

31
21
11

21

31

21

13

22

32
22
14

32
22
12

22

32

22
14

NM01

NM12

NM03

NM11,

NM11..C2069

NM02

21
11

22
12

11

21

12

22

NM02..C2069

Not actuated

Actuated

Technical data

Parameter

Value

Housing material

Reinforced thermoplastic

Degree of protection  

acc. to IEC 60529

IP67

Mech. operating cycles

30 x 10

6

Ambient temperature

-20 … +80 °C

Degree of contamination  

(external, acc. to EN 60947-1) 3 (industrial)
Installation position

Any

Approach speed, max.

60 m/min

Actuating force at 20 °C

15 N

Actuation frequency, max.

5000/h

Switching principle

Slow-action switching contact

Contact material

Silver alloy, gold flashed

Connection

Screw terminal

Conductor cross-section  

(rigid/flexible)

0.34 mm

2

 … 1.5 mm

2

Rated impulse withstand 

voltage

U

imp

 = 2.5 kV

Rated insulation voltage

U

i

 = 250 V

Conditional short-circuit current 100 A
Switching voltage, min.,  

at 10 mA

12 V

Utilization category acc. to EN 60947-5-1
AC-15

4 A 230 V

DC-13

4 A 24 V

Switching current, min., at 24 V 1 mA
Short circuit protection  

(control circuit fuse)  

according to IEC 60269-1

4 A gG

Conventional thermal current I

th

4 A

Reliability values acc. to EN ISO 13849-1
B

10d

2 x 10

7

Figure 4:  Dimension drawing and travel diagrams NM01WO / NM..WO..C2069

17

28

32

10

25

18

16,5

4,2

+1

M=0,6Nm

K

0

1

2

3,2

4

21

-2

2

*

5

1,

5

12,5

25

32

77

,5

M16x1,5

M=0,6Nm

M=0,6Nm

0

1

2

3,2

4

21

-2

2

31

-3

2

0

1

2

3,2

4

13

-1

4

21

-2

2

NM02

(C2069)

NM01

NM11

(C2069)

Actuating direction

End position Fr

ee position

* Fixed positioning for 

safety-related applications 

(M5)

Figure 5:  Dimension drawing and travel diagrams NM01RB / NM..RB..C2069

17

32

36

25

18

16,5

R6

4,2

M=0,6Nm

0

1

2

3,2

4

21-2

2

*

1,

5

12,5

25

32

81,

5

M16x1,5

5

A

B

M=0,6Nm

M=0,6Nm

M=0,6Nm

30˚

m

ax

.

32

+0,5

0

1

2

3,2

4

21-2

2

31-3

2

0

1

2

3,2

4

13-14

21-2

2

NM02

(C2069)

NM01

NM11

(C2069)

End position Fr

ee position

* Fixed positioning for 

safety-related applications 

(M5)

Summary of Contents for NM WO Series

Page 1: ...Betätigungselements aus der Ruhestellung in die Endstellung werden die Schalt kontakte betätigt Die Sicherheitskontakte werden dabei zwangsweise geöffnet siehe Bild 3 Schaltzustände Die detaillierten Schaltzustände für Ihren Schalter finden Sie in Bild 3 Dort sind alle verfügbaren Schal telemente beschrieben Betätigungselement in Ruhestellung Die Sicherheitskontakte sind geschlossen Betätigungsele...

Page 2: ... 14 32 22 12 22 32 22 14 NM01 NM12 NM03 NM11 NM11 C2069 NM02 21 11 22 12 11 21 12 22 NM02 C2069 Nicht betätigt Betätigt Technische Daten Parameter Wert Gehäusewerkstoff Glasfaserverstärkter Thermoplast Schutzart nach IEC 60529 IP67 Mech Schaltspiele 30 x 106 Umgebungstemperatur 20 80 C Verschmutzungsgrad extern nach EN 60947 1 3 Industrie Einbaulage beliebig Anfahrgeschwindigkeit max 60 m min Betä...

Page 3: ...3 14 21 22 31 32 5 1 5 12 5 25 32 108 5 12 5 16 M 0 6Nm M 0 6Nm NM03 NM12 NM02 NM11 Betätigungs richtung Endstellung Ruhestellung fixierte Positionierung für Sicherheitsanwendungen M5 Bild 7 Maßzeichnung und Schaltwegdiagramme NM11RB NM02RB NM12RB NM03RB 32 36 R 6 25 18 16 5 17 4 2 M16x1 5 M16x1 5 M 0 6Nm 0 1 2 3 2 4 11 12 21 22 31 32 0 1 2 3 2 4 13 14 21 22 31 32 5 1 5 112 5 12 5 25 32 12 5 16 A ...

Page 4: ...on 7 f f Mounting electrical connection and setup only by authorized personnel possessing special knowledge about handling safety components Function The safety switch monitors the position of movable safety guards The switching contacts are actuated when the actu ating element is moved from the free position to the end position The safety contacts are positively opened in this process see Figure ...

Page 5: ...ng func tions 21 13 21 31 11 21 31 31 21 13 21 22 14 22 32 12 22 32 32 22 14 22 21 31 21 13 31 21 11 21 31 21 13 22 32 22 14 32 22 12 22 32 22 14 NM01 NM12 NM03 NM11 NM11 C2069 NM02 21 11 22 12 11 21 12 22 NM02 C2069 Not actuated Actuated Technical data Parameter Value Housing material Reinforced thermoplastic Degree of protection acc to IEC 60529 IP67 Mech operating cycles 30 x 106 Ambient temper...

Page 6: ...4 11 12 21 22 31 32 0 1 2 3 2 4 13 14 21 22 31 32 5 1 5 12 5 25 32 108 5 12 5 16 M 0 6Nm M 0 6Nm NM03 NM12 NM02 NM11 Actuating direction End position Free position Fixed positioning for safety related applications M5 Figure 7 Dimension drawing and travel diagrams NM11RB NM02RB NM12RB NM03RB 32 36 R 6 25 18 16 5 17 4 2 M16x1 5 M16x1 5 M 0 6Nm 0 1 2 3 2 4 11 12 21 22 31 32 0 1 2 3 2 4 13 14 21 22 31...

Reviews: