EUCHNER NM HB Series Operating Instructions Manual Download Page 5

5

Operating Instructions

Safety Switch NM..HB

Inspection and service

 WARNING

Danger of severe injuries due to the loss of the 

safety function.

 

f

If damage or wear is found, the complete switch 

must be replaced. Replacement of individual 

parts or assemblies is not permitted.

 

f

Check the device for proper function at regular 

intervals and after every fault. For informa-

tion about possible time intervals, refer to 

EN ISO 14119:2013, section 8.2.

Inspection of the following is necessary to ensure 

trouble-free long-term operation:

 

f

correct switching function

 

f

secure mounting of all components

 

f

damage, heavy contamination, dirt and wear

 

f

sealing of cable entry

 

f

loose cable connections or plug connectors.

Info

: The year of manufacture can be seen in the 

bottom, right corner of the type label.

Exclusion of liability and warranty

In case of failure to comply with the conditions for 

correct use stated above, or if the safety regula-

tions are not followed, or if any servicing is not 

performed as required, liability will be excluded and 

the warranty void.

Notes about 

This device is intended to be used with a Class 2 

power source in accordance with UL1310. 
As an alternative an LV/C (Limited Voltage/Current) 

power source with the following properties can be 

used:
This device shall be used with a suitable isolating 

source in conjunction with a fuse in accordance 

with UL248. The fuse shall be rated max. 3.3  A 

and be installed in the max. 30 V DC power supply 

to the device in order to limit the available current 

to comply with the UL requirements

 1)

. Please note 

possibly lower connection ratings for your device 

(refer to the technical data). A maximum power 

value of 100 VA according to Tab. 32.1 (UL508) 

must not be exceeded.

1) Note on the scope of the UL approval: the devices have been 

tested as per the requirements of UL508 and CSA/ C22.2 no. 14 

(protection against electric shock and fire).

EU declaration of conformity

The declaration of conformity is part of the operating 

instructions, and it is included as a separate sheet 

with the device. 
The original EU declaration of conformity can also 

be found at: www.euchner.com

Service

If servicing is required, please contact:
EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

70771 Leinfelden-Echterdingen

Germany

Service telephone

:

+49 711 7597-500

E-mail

:

[email protected]

Internet

:

www.euchner.com

Technical data

Parameter

Value

Housing material

Reinforced thermoplastic

Degree of protection

IP67

Mech. operating cycles

20 x 10

6

Ambient temperature

-20 … +80 °C

Degree of contamination  

(external, acc. to EN 60947-1)

3 (industrial)

Installation orientation

Any

Approach speed, max.

60 m/min

Actuating force at 20 °C

0.1 N

Actuation frequency, max.

5,000/h

Switching principle

Slow-action switching 

contact

Contact material

Silver alloy, gold flashed

Connection

Screw terminal

Conductor cross-section  

(rigid/flexible)

0.34 mm

2

 … 1.5 mm

2

Rated impulse withstand voltage

U

imp

 = 2.5 kV

Rated insulation voltage

U

i

 = 250 V

Conditional short-circuit current

100 A

Switching voltage, min., at 10 mA

12 V

Utilization category acc. to EN 60947-5-1
AC-15

4 A 230 V

DC-13

4 A 24 V

Switching current, min., at 24 V

1 mA

Short circuit protection (control circuit 

fuse) acc. to IEC 60269-1

4 A gG

Convent. thermal current I

th

4 A

Reliability values acc. to EN ISO 13849-1

B

10D

at DC-13  100 mA/24 V

2 x 10

7

Fig. 3:  Switching elements and switching functions

21

13

21

31

11

21

31

31
21

13

21

22

14

22

32

12

22

32

32
22

14

22

21

31
21

13

31
21
11

21

31

21

13

22

32
22
14

32
22
12

22

32

22
14

NM01

NM12

NM03

NM11,

NM11..C2069

NM02

21
11

22
12

11

21

12

22

NM02..C2069

Not actuated

Actuated

Fig. 4:  Changing the lever arm

The lever arm can be adjusted to positions every 10°. Depending on the application, the lever with 

roller can also be rotated to the outside or the inside. After setting the required approach direction, 

fasten the lever arm using the screw.

Fig. 5:  Changing the switching direction

Simultaneously press 

and rotate the disk

Rotate the actuating 

element

Left switch-

ing

Left/right switching

(default setting)

Right 

switching

-90°

+90°

Summary of Contents for NM HB Series

Page 1: ... werden die Schalt kontakte betätigt Die Sicherheitskontakte werden dabei zwangsweise geöffnet siehe Bild 3 Schaltzustände Die detaillierten Schaltzustände für Ihren Schalter finden Sie in Bild 3 Dort sind alle verfügbaren Schal telemente beschrieben Betätigungselement in Ruhestellung Die Sicherheitskontakte sind geschlossen Betätigungselement in Endstellung Die Sicherheitskontakte sind geöffnet M...

Page 2: ...gen von UL508 und CSA C22 2 no 14 Schutz gegen elektrischen Schlag und Feuer geprüft EU Konformitätserklärung Die Konformitätserklärung ist Bestandteil der Be triebsanleitung und liegt dem Gerät als separates Blatt bei Die originale EU Konformitätserklärung finden Sie auch unter www euchner de Service Wenden Sie sich im Servicefall an EUCHNER GmbH Co KG Kohlhammerstraße 16 70771 Leinfelden Echterd...

Page 3: ...28 5 25 46 0 35 6 0 6 5 0 4 5 6 0 6 5 35 A Standard B C D M 0 6Nm M 0 6Nm 41 1 0 13 14 21 22 31 32 11 12 21 22 31 32 NM03 NM02 NM12 NM11 fixierte Positionierung für Sicherheits anwendungen M5 Bild 7 Maßzeichnung und Schaltwegdiagramme NM01HB NM C2069 41 1 0 21 22 1 5 25 18 16 5 17 27 25 R6 4 2 M 0 6Nm M 1 Nm 0 35 6 0 6 5 5 12 5 32 8 32 97 5 25 46 M16x1 5 A Standard B C D M 0 6Nm M 0 6Nm 0 35 6 0 6...

Page 4: ... safety contacts are positively opened in this process see Fig 3 Switching states The detailed switching states for your switch can be found in Fig 3 All available switching elements are described there Actuating element in free position The safety contacts are closed Actuating element in end position The safety contacts are open Mounting NOTICE Device damage due to improper mounting and unsuitabl...

Page 5: ...mity The declaration of conformity is part of the operating instructions and it is included as a separate sheet with the device The original EU declaration of conformity can also be found at www euchner com Service If servicing is required please contact EUCHNER GmbH Co KG Kohlhammerstraße 16 70771 Leinfelden Echterdingen Germany Service telephone 49 711 7597 500 E mail support euchner de Internet...

Page 6: ...A Standard B C D M 0 6Nm M 0 6Nm 41 1 0 13 14 21 22 31 32 11 12 21 22 31 32 NM03 NM02 NM12 NM11 Fig 6 Dimension drawing and travel diagrams for NM11HB NM02HB NM12HB NM03HB Fixed posi tioning for safety related applications M5 41 1 0 21 22 1 5 25 18 16 5 17 27 25 R6 4 2 M 0 6Nm M 1 Nm 0 35 6 0 6 5 5 12 5 32 8 32 97 5 25 46 M16x1 5 A Standard B C D M 0 6Nm M 0 6Nm 0 35 6 0 6 5 21 22 31 32 NM02 C2069...

Reviews: