![EUCHNER N1A Series Operating Instructions Manual Download Page 5](http://html.mh-extra.com/html/euchner/n1a-series/n1a-series_operating-instructions-manual_2434860005.webp)
5
Operating Instructions
Precision Single Limit Switches N1A
Inspection of the following is necessary to ensure
trouble-free long-term operation:
f
correct switching function
f
secure mounting of all components
f
precise adjustment of trip dog in relation to single
limit switch
f
damage, heavy contamination, dirt and wear
f
sealing of cable entry
f
loose cable connections or plug connectors.
Information
: The year of manufacture can be seen
in the bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety instruc-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and applications as per the requirements
of
, a copper wire for the temperature range
60/75 °C is to be used.
The following information applies to devices
with plug connector:
For use and applications as per the requirements of
, a class 2 power supply according to UL1310
must be used. Connection cables for safety switches
installed at the place of use must be separated
from all moving and permanently installed cables
and un-insulated active elements of other parts
of the system which operate at a voltage of over
150 V. A constant clearance of 50.8 mm must be
maintained. This does not apply if the moving cables
are equipped with suitable insulation materials which
possess an identical or higher dielectric strength
compared to the other relevant parts of the system.
EU declaration of conformity
The declaration of conformity is part of the oper-
ating instructions, and it is included as a separate
sheet with the unit.
The EU declaration of conformity can also be
found at: www.euchner.com
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone
:
+49 711 7597-500
Fax
:
+49 711 753316
:
Internet
:
www.euchner.de
Technical data
Parameter
Value
Housing material
Die-cast aluminum, anodized
Plunger material
Stainless steel
Degree of protection acc. to
IEC 60529
IP 67
Mech. operating cycles
- Switch
30x10
6
at N1A.2588
1x10
6
- Switching element
ES502E /
ES508E
30x10
6
ES514
1x10
6
ES588
10x10
6
Switching frequency
ES502E
300 min
-1
ES508E/ES514
50 min
-1
ES588
20 min
-1
Ambient temperature
ES502E
-5...+80°C
ES508E/ES514
-25…+80°C
ES588
-25…+70°C
Installation position
Any
Max. approach speed
Plunger Chisel D
40 m/min
Roller R (slide bearing) 80 m/min
Roller B (ball bearing) 120 m/min
Dome W/ball K
10 m/min
Extended roller
20 m/min
Min. approach speed
0.01 m/min
Actuating force
ES502E
≥
20 N
with switching element
ES508E
≥
15 N
ES514
≥
30 N
2 x ES588
≥
20 N
Switching element
ES502E
1 NO c 1 NC contact
ES508E
1 positively driven contact
ES514
1 NO c 1 positively
driven contact
ES588
1 positively driven contact
Switching principle
ES502E/ES514
Snap-action switching contact
ES508E/ES588
Slow-action switching contact
Hysteresis
ES502E
0.8 mm
ES514
0.6 mm
Contact material
ES502E/ES508E/ES514
Silver alloy, gold flashed
ES588
Fine silver
Connection
N1A...M
Screw terminals
N1A...SVM5...
Plug connector M12
Tightening torque of screw terminal
ES588 (slot head screw)
0.3 Nm
ES502E/ES508E/ES514
(cross-head screw)
0.6 Nm
Conductor cross-section
0.34 ... 1.5 mm
2
Rated insulation voltage
with cable entry
U
i
= 250 V
with plug connector
- 4-pin
- 5-pin
U
i
= 250 V
U
i
= 50 V
Rated impulse withstand voltage with cable entry
ES508E/ES514
U
imp
= 4 kV
ES502E/ES588
U
imp
= 2.5 kV
with plug connector
- 4-pin
- 5-pin
U
imp
= 2 kV
U
imp
= 1.5 kV
Utilization category of switching element acc. to IEC 60947-5-1
ES502E
AC-12
250 V 8 A
ES502E/ES508E
AC-15
230 V 6 A
DC-13
24 V
6 A
ES514
AC-15
230 V 2.5 A
DC-13
24 V
6 A
ES588
AC-15
230 V 4 A
DC-13
24 V
3 A
Min. switching current
at DC 24 V
ES514
5 mA
ES508E
10 mA
at DC 12 V
ES502E
10 mA
at DC 5 V
ES588
1 mA
Conventional thermal current I
th
ES502E
8 A
ES508E/ES514/ES588
10 A
Short circuit protection acc. to IEC 60269-1 (control circuit fuse)
ES502E
8 A gG
ES508E/ES588
10 A gG
ES514
6 A gG
Conditional short-circuit current 100 A
Indicator LED
LE060
AC/DC 12 - 60 V
(only with ES502E/ES508E)
LE110
AC 110 V ± 15%
LE220
AC 220 V ± 15%
Reliability values according to EN ISO 13849-1
for switching elements
ES508E
ES588
ES514
B
10d
2 x 10
7
2 x 10
6