Operating Instructions
Safety System MGBS-P-I-AP…
24
(Translation of the original operating instructions) 2527247-01-09/19
6. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
6.1.
Technical data for interlocking module MGBS-P-I-AP
Parameter
Value
Unit
min.
typ.
max.
General
Material of interlocking module
- Head
- Housing
Die-cast zinc
Reinforced thermoplastic
Installation orientation
Any
Degree of protection
IP67/IP69/IP69K
(screwed tight with the related mating connector)
Safety class acc. to EN IEC 61558
III
Degree of contamination
3
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at UB = 24 V
-20
-
+55
°C
Handle module approach speed, max.
20
m/min
Actuating/extraction force at 20 °C
10/20
N
Weight
Approx. 0.23
kg
Connection
1 plug connector M12, 8-pin
Operating voltage UB (reverse polarity protected, regulated,
residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption I
UB
40
mA
For the approval acc. to UL the following applies
Operation only with UL class 2 power supply, or equivalent measures
Switching load acc. to UL
DC 24 V, class 2
External fuse (operating voltage UB)
1)
0.25
-
8
A
Rated insulation voltage U
i
-
-
50
V
Rated impulse withstand voltage U
imp
-
-
0.5
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 60947-5-3
Ready delay
-
-
1
s
Risk time
-
-
260
ms
Switch-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
0.35
ms
Frequency band
120 … 130
kHz
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U
FO1A
/U
FO1B
2)
V DC
HIGH U
FO1A
/U
FO1B
UB - 1.5
-
UB
LOW U
FO1A
/U
FO1B
0
-
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN 60947-5-2
DC-13 24V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Switching frequency
3)
0.5
Hz
Monitoring outputs OI, OD
p-switching, short circuit-proof
Output voltage
0.8 x UB
-
UB
V DC
Max. load
-
-
50
mA
Reliability values acc. to EN ISO 13849-1
Category
4
Performance Level (PL)
e
PFH
D
4.1 x 10
-9
/h
Mission time
20
years
1) Trip characteristic medium slow-blow.
2) Values at a switching current of 50 mA without taking into account the cable lengths.
3) Corresponds to the actuation frequency.