10. Mounting
CAUTION
Interlocking modules must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Interlocking modules and handle module must not be used as an end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about fastening the interlock-
ing module and the handle module.
Ì
Protect the interlocking module against damage, as well as penetrating foreign objects such as
swarf, sand and blasting shot, etc.
Ì
Observe the min. door radii (see chapter
7.4. Dimension drawing (example illustration) on page
).
Ì
Observe the tightening torque for fastening the interlocking module (max.1.4 Nm).
10.1. Mounting examples
6 Nm
1 Nm
Figure 2:
Mounting situation without escape release
6 Nm
6 Nm
1 Nm
Figure 3:
Mounting situation with escape release