21
2124662-03-05/18 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP-L.-AS1
EN
13. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
13.1. Technical data for safety switch CTP-AS
Parameter
Value
Unit
min.
typ.
max.
General
Material
- Switch head
- Switch housing
Die-cast zinc
Reinforced thermoplastic
Installation position
Any
Degree of protection
IP 67/IP 69/IP 69K
(screwed tight with the related mating connector)
Safety class according to EN IEC 61558
III
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at UB = 24 V
-20
-
+55
°C
Actuator approach speed, max.
20
m/min
Actuating/extraction/retention force at 20 °C
10/20/20
N
Locking force F
max
1)
3900
N
Locking force F
Zh
1)
according to EN ISO 14119
F
Zh
= F
max
/1.3 = 3,000
N
Weight
Approx. 0.42
kg
Connection
Plug connector M12, 4-pin
For the approval according to UL the following applies
Operation only with UL class 2 power supply, or equivalent measures
Resilience to vibration
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 60947-5-3
Ready delay
-
-
1
s
Risk time
-
-
260
ms
Switch-on time
-
-
400
ms
Frequency band
120 … 130
kHz
Solenoid
Auxiliary voltage
24 +10%/-15% (PELV)
V DC
Current consumption with auxiliary voltage
400
mA
Duty cycle
100
%
AS-Interface data
EA code: 7
ID code: B
AS-i operating voltage
26.5
-
31.6
V DC
Total current consumption from AS-i
CTP-..-AS.A
-
-
450
mA
CTP-..-AS.B
-
-
50
Valid AS-Interface addresses
1 - 31
AS-Interface inputs
Acc. to ASi Safety at work
Influenced by door position
CTP-..-AS1..
D0, D1
CTP-..-AS2..
D0, D1, D2, D3
Influenced by guard locking
CTP-..-AS1..
D2, D3
CTP-..-AS2..
D0, D1, D2, D3
AS-Interface outputs
Guard locking solenoid
D0 (1 = solenoid energized)
Reliability values acc. to EN ISO 13849-1
Mission time
20
years
Monitoring of guard locking and the guard position
Category
4
Performance Level (PL)
e
PFH
D
4.1 x 10
-9
/h
Control of guard locking
Category
Depends on external control
Performance Level (PL)
PFH
D
1) Dependent on the actuator used.
13.1.1. Typical system times
Please refer to the technical data for the exact values.
Ready delay
: After switching on, the device carries out a self-test. The system is ready for operation only after this time.
Switch-on time of safety output
s: The max. reaction time t
on
is the time from the moment when the guard is locked to
the moment when the safety outputs switch on.
Risk time according to EN 60947-5-3
: If an actuator moves outside the operating distance, transmission of the code
sequence on the corresponding safety switch is deactivated at the latest after the risk time.