![EUCHNER CTM-I2-BP Operating Instructions Manual Download Page 10](http://html.mh-extra.com/html/euchner/ctm-i2-bp/ctm-i2-bp_operating-instructions-manual_2434751010.webp)
Operating Instructions
Transponder-Coded Safety Switch CTM-I2-BP/BR
10
(translation of the original operating instructions) MAN20001437-01-10/21
6.4.
Switching states
6.4.1. Switching states with control via the control input IMP
The detailed switching states for your switch can be found in chapter
15. Status and error messages on page 28
safety outputs, signals and display LEDs are described there.
Guard closed and locked
Guard closed and not locked
Guard being opened
Guard open
Control input IMP
on
off
off
irrelevant
Safety outputs FO1A and FO1B
on
on
off
off
Guard locking signal OL
on
off
off
off
Door position signal OD
on
on
on
off
6.4.2. Switching states with control via IO-Link communication
Guard closed and locked
Guard closed and not locked
Guard being opened
Guard open
Bit
CL
1
0
0
irrelevant
Safety outputs FO1A and FO1B
on
on
off
off
Guard locking signal OL
on
off
off
off
Door position signal OD
on
on
on
off