(Translation of the original operating instructions) 2525462-01-01/20
11. System status table
Operating mode
Actuator/door position
Safety outputs FO1A and
FO1B
Guar
d locking monitoring
output OL
Door monitoring output OD
LED indicator
Output
State
ST
ATE (gr
een)
DIA (r
ed) and diag
-
nostic output OI
LOCK (yellow)
Normal operation
off
off
off
off
5 Hz
Power Up
closed
on
on
on
Normal operation, door closed and locked
closed
off
off
on
1 x in-
verse
Normal operation, door closed and
not
locked
open
off
off
off
1 x
Normal operation, door open
open
off
off
off
1 x
1 x
Normal operation, door open, ready for guard locking
Teach-in operation
(only unicode)
open
off
off
off
3 x
Device in teach-in standby
closed
off
X
on
1 Hz
Teach-in operation
X
off
X
off
Positive acknowledgment after completion of teach-in
operation
Fault display
X
off
off
X
1 x
or
1 x in-
verse
Fault in the teach-in operation (only unicode)
Actuator removed from the actuating range prior to the
end of the teach-in operation or faulty actuator detected.
X
off
X
X
2 x
Input fault
(e.g. missing test pulses, illogical switch state from
previous switch in the switch chain)
X
off
off
off
3 x
Read error
(e.g. actuator faulty)
X
off
X
X
4 x
Output fault
(e.g. short circuit, loss of switching ability)
X
off
X
X
5 x
Environment error
(e.g. operating voltage or operating temperature too high)
X
off
X
X
2 x
Solenoid control input error
X
off
X
X
1 x
Plausibility error
X
off
off
off
X
Internal error
X
off
off
off
5 Hz
Operator error
X
off
X
X
1 x in-
verse
1 x in-
verse Locking element stuck
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 s at 10 Hz
3 x
LED flashes three times, and this is then repeated
LEDs flash alternately
X
Any state