5 Mounting
Warning!
Mounting must be performed only by authorized personnel.
After mounting, again check the Electronic-Key adapter for firm seating and correct sealing on the front
panel.
5.1 Electronic-Key adapter compact
Attention!
To achieve the degree of protection IP67, it is necessary to install the key adapter in a clean, flat metal
plate at least 2 mm thick and to tighten the screws with a tightening torque of 0.25 ... 0.35 Nm.
Suitable strain relief must be provided for the connecting cables in order to avoid damage to the
connection sockets or malfunctions.
The Electronic-Key adapter is intended for mounting in control panels with a cut-out measuring
33 mm x 68 mm according to DIN IEC 61554 (see chapter 4.1). The device is fastened using screw clamp
elements from the rear side of the panel.
Information!
The screw clamp elements for front panel mounting are included with the Electronic-Key adapter.
1. Insert the Electronic-Key adapter,
with seal already bonded in place
, into the mounting cut-out from the
front.
2. Insert screw clamp elements into the housing of the Electronic-Key adapter from the side up to the stop and
tighten with 0.25 …0.35 Nm.
Attention!
The device may be damaged if the tightening torque exceeds 0.35 Nm.
5.2 Electronic-Key adapter FHM
Attention!
To achieve the degree of protection IP 69K, it is necessary to install the FHM Electronic-Key adapter in
a clean, flat metal plate at least 2 mm thick and to tighten the central fixing nut with a tightening torque
of 2 Nm.
Suitable strain relief must be provided for the connecting cables in order to avoid damage to the
connection sockets or malfunctions.
The Electronic-Key adapter is intended for mounting in control panels with a cut-out Ø 22.5 mm (see chapter
4.2).