Scale CALIBRATION
To calibrate the scale, you need a 500g calibration weight (not included). We recommend to recalibrate on
a regular basis (depending on use).
Disconnect grinder from power supply by pressing the ON‐/OFF‐button on the bottom side
Remove Portafilter holder from center hook
Press 1 while reconnecting grinder to power supply by pressing ON‐/OFF‐button
Wait for
CAL
to appear on the display
Press START
Calibration is completed once
PA5
is displayed on screen
Slide Portafilter holder onto center hook
Software UPDATE
(Apple‐Smartphones)
ATTENTION!
NEVER interrupt an Update! Disconnecting the grinder from the power supply during an update may
cause major damage to the power control (no warranty).
If updating your software for the first time: Install the
etzMAX‐Updater
on your
Apple
‐Smartphone!
Before starting the Update, press STOP (to prevent the grinder from going into sleep mode)
Follow the Instructions according to the APP.
The update takes around 1‐2 minutes. Make sure, nor your grinder neither your smartphone go into
sleep mode during the Update.
Once the update is finished, unplug the grinder. The update is installed, once you plug it back in.
5. CLEANING and CARE
ATTENTION!
To ensure proper function of the coffee grinder, ensure that the coffee grinder is properly cleaned at
regular intervals in accordance with the operating instructions. Long pauses in use may result in
remaining coffee powder getting dense and hard and thus causing blockades when restarting.
NOTE
: The colver lid does not need to be opened to clean the grinder.
5.1. Cleaning the Conical Burrs and Grinding Chamber
The bean hopper and grind size adjustment (14) must be removed or disassembled before burrs and
grinding chamber can be cleaned.