15
26868-01A
T-Max® 1A and 3A Remote Systems
In single sunbed installations, the T-Max® 1A
and 3A can offer the same control as the T-
Max® Manager, eliminating the need for a
Manager. If you’re using a 1A in this manner,
it must have a chip labelled “master” installed
on its circuit board. The remote control
bypass plug must not be used in this configu-
ration. The 3A may be used as a “master” with
no modification.
After you have set the T-Max® 1A’s, or 3A’s,
address to “0” (refer to your T-Max® user’s
guide) and the sunbed’s address to “1” (see
right), simply connect the RJ-22 modular
cables, described in the T-Max® user’s guide,
directly into either port located on the back of
the sunbed and either port on the back of the
T-Max® 1A or 3A. See
figure 2
.
Setting the address manually
Before connecting your sunbed to the T-Max®
Manager or T-Max® 1A or 3A, the address of
your sunbed must first be set. Set the “id” man-
ually as described below.
Setting the “id”
1. Make sure no cables are plugged into
your sunbed’s remote ports.
2. Remove and reapply power to the unit.
3. Press and hold the stop button, located
on the sunbed display, for three seconds
and release. The display should indicate
an “id” number from “oF” to “252”.
4. If you are using a T-Max® 1A or 3A as a
“master” remote, the “id” of the sunbed
must be set to “1”. If you are using a T-
Max® Manager each sunbed must be
assigned a different “id”. To set the “id”
press the timer button, to count up, or
the body fan control button, to count
down, until the desired number is
achieved.
5. Press the stop button to return to the
normal display mode.
1-99
100-199
200-252
figure 2
NOTE: A T-Max® 1A
with a “master” chip
can be substituted for
a 3A in
figure 2
.
Installation - Remote Connections