VI. Maintenance and Calibration 

 

Calibration 

No manufacturer conducted calibration is required. 

 

Maintenance & Repair 

To return equipment to ETS for maintenance it is first necessary to obtain a RMA number, 
please call 215-887-2196 or email [email protected] 

 

 

VII.  Desiccant   

 
 

CHANGING THE DESICCANT 

 
1. Disconnect the tubing from both sides of the column. 
 
2. Lift the column straight up and off of the box. 
 
3. Turn the column over, lid up, and slowly unscrew the lid. 
   
4. Remove the metal retainer, O-ring, and spring on top of the desiccant. 
 
5. Pour out old desiccant, refill, tapping the column gently on a table to help settle the desiccant. 
 
6. Replace the metal retainer, O-ring, and spring.  Tighten lid. 
 
7. Replace the column onto the box and reconnect tubing. 
 

 

 
RENEWING THE DESICCANT 

 
The desiccant can be renewed approximately ten (10) times before having to be replaced. The granules should 

be removed from the drying column and spread evenly, one granule deep on a tray. The desiccant should then be 

heated for approximately one (1) hour at about 400° F (200° C), or until all the indicating granules turn from gray 

to blue. The material should be allowed to cool in an airtight container before refilling the plastic column. 

 
 

Summary of Contents for 5461

Page 1: ...D01083 Revision A 2019 10 28 Desiccant Pump Dehumidification System Model 5461 Operating Manual...

Page 2: ...33 ENV GURU 833 368 4878 Table of Contents I Important Safety Information 3 II Description of Contents 4 III Set Up Guide 5 IV Operation 7 V Description and Specifications 7 VI Maintenance and Calibra...

Page 3: ...AUTION DO NOT OPERATE WITH COVERS OR PANELS REMOVED Voltages inside the equipment consist of line mains that can be anywhere from 100 240VAC DO NOT OPERATE WITH SUSPECTED EQUIPMENT FAILURES If any odo...

Page 4: ...ification System is housed in a 7 W x 7 L x 5 H plastic enclosure with vibration isolating feet MS desiccant column 1 L Molecular sieve 20 indicating Tubing section 1 9 Tubing o d short piece of tubin...

Page 5: ...fans will already be installed For other installations it is recommended that a 32 110 cfm fan s be installed to evenly distribute the air within the chamber Step 1 Mount Desiccator Column Place the...

Page 6: ...into the bottom of the fitting to avoid leaks Step 4 Plug the unit power cord into the DECREASE or DEHUMIDIFY outlet on the rear of the Model 5100 or 5200 Humidity Controller Step 5 Set Humidity Set y...

Page 7: ...ed to within 0 1 RH of the set point A clear plastic column filled with 1 Liter of renewable Molecular Sieve MS desiccant is mounted to the top of the enclosure The desiccant removes moisture from the...

Page 8: ...e metal retainer O ring and spring on top of the desiccant 5 Pour out old desiccant refill tapping the column gently on a table to help settle the desiccant 6 Replace the metal retainer O ring and spr...

Page 9: ...m any cause whatsoever This warranty becomes null and void should the equipment or any part thereof be abused or modified by the customer of if used in any application other than that for which it was...

Reviews: