![ETS NORD NORDcanopy Installation Manual Download Page 20](http://html.mh-extra.com/html/ets-nord/nordcanopy/nordcanopy_installation-manual_2434453020.webp)
www.etsnord.com
20
RDM-064-0722
®
NORD
canopy
|
UV 1.0 installation guide
6.2 UV-C lamp electrical disconnection
Disconnect the lamp from the power circuit by first twisting the locking rings counterclockwise, then pulling the
connectors downward. Never pull on the cables themselves, only the connectors.
6.3 UV-C lamp removal from exhaust chamber
Release the lamp from the clamp attachments by unscrewing the screw.
2x
To install a new UV-C lamp, see chapter 2 “Installation of UV-C lamps”. After installing new lamp start the
system and ensure that it functions properly by observing the Control Panel.
NB! In the case of a running device, UV shields and filters must never be
removed due to the risk of ultraviolet radiation!
NB! Lamps should only be handled with protective gloves and eyewear.