GSM Gateway ETS-16G User
’s Manual
Shenzhen Etross Telecom Co.,Ltd
23
BCCH roam
To set BCCH roaming if you enable it on
Valid Dbm
To set the base station dbm value,if the value is more than this
value,the base station will not accept Bcch roam, only the value is less
than this value, it will roam to this base station
Roam cycle
To set rotate/cycle after specified minutes .e.g.10 minutes means rotate
to next base station after 10 minutes.
BCCH list
Means you can input the BCCH list in the blank, then the base station
roam will do in these BCCH list . You can get the BCCH list parameters
from the Status\BCCH
Save
To save the setting
white
To permit the BCCH roam in these specified BCCH list
Black
To permit the BCCH roam in other BCCH list expect the specified BCCH
list
4.5 Trunk
4.5.1 Trunk Setting
Trunk or IP trunk interface permits us to add remote IP of softs witch, SIP server which will send
call traffics to ETS-16G gateway. In one ETS-16G GSM gateway,we can setup 1 or several trunks .
User can add remote soft switch or IP server by “account” or by “peer”, to realize the connection
with remote soft switch or IP server.
Figure 4-5-1 Trunk setting
Table 4-5-1 Description of Trunk setting
Trunk Setting
To set the trunk parameters
Trunk enable
To open (on) /Close(off) the Trunk