background image

-3-

Hardened alloy steel housing

45-tooth reversible ratchet: wrench
torques in both clockwise and
counterclockwise direction

EASY TO READ SCALES:

Ergonomic grip

Torque adjusting knob: Pull out to

unlock, turn clockwise to increase

torque, counterclockwise to decrease
torque. Push back in to lock.

TARGET

ft.lb

TARGET

in.lb

TARGET

N.m

TARGET

kg.cm

Battery compartment (2 X LR44)

Foot Pounds

Inch Pounds

Newton Meters

Kilogram Centimeters

Red Key:

 Press once to turn ON, press and

hold to turn OFF. Auto Off in 10 minutes.

Green Key.

 Press to change torque

units, press and hold to turn backlight
ON

Battery isolation plastic tab: Pull out and
discard to engage the battery (New

wrenches only!)

PULL

UNITS
LIGHT

Summary of Contents for QuadTork Torque

Page 1: ...INSTRUCTIONS QuadTork Torque Wrenches with Electronic Digital Display www etork com TM R eTORK ...

Page 2: ...wrench to the exact torque units your specifications call for or you will severely under torque or over torque causing severe damage to the equipment you are working on 5 Do not disassemble the wrench for any reason Highly stressed internal components may cause severe injury when released in an unintended manner 6 The wrench should be re calibrated periodically The calibration of the wrench should...

Page 3: ...kwise to decrease torque Push back in to lock TARGET ft lb TARGET in lb TARGET N m TARGET kg cm Battery compartment 2 X LR44 Foot Pounds Inch Pounds Newton Meters Kilogram Centimeters Red Key Press once to turn ON press and hold to turn OFF Auto Off in 10 minutes Green Key Press to change torque units press and hold to turn backlight ON Battery isolation plastic tab Pull out and discard to engage ...

Page 4: ...ied by the manufacturer of the equipment you are working on 4 Push the adjusting knob in to lock the selected reading 4 New battery about 30 hours remaining About 10 hours remaining Wrench can not operate Insert two new LR44 or equivalent AG13 357 SR44 A76 LR1154 batteries Make sure the ends are toward the spring To optimize battery life do not use backlight and remove batteries when the wrench is...

Page 5: ...ench Consequently the torque set on the wrench must be corrected using the formula shown 2 An attachment as shown below is a drive extension which does not affect the torque and no correction is required However be careful when using a long extension to assure that the extension stays in line with the drive You may support a long extension with your free hand with no measurable affects on the accu...

Page 6: ...ired effort you need to use both hands put the other hand on the top of the first hand never on any other part of the wrench 4 Apply slow and steady pull or push until the wrench momentarily releases with or without a distinct click sound Release the pressure right at this point DO NOT OVERTORQUE SAFETY WARNING Overtorqued or defective fasteners sockets as well as the wrench itself may suddenly br...

Page 7: ...th instead 5 With the exception of the ratchet mechanism there are no user serviceable parts For repair and or re calibration information call 1 678 439 8782 LIFETIME WARRANTY The manufacturer warrants this product against defects in material and workmanship except for re calibration and for damage resulting from over torquing and other abuse Calibration is guaranteed for a period of one year from...

Page 8: ..._______________________ Serial Number ___________________________ NOTES and SERVICE RECORD CERTIFICATION This torque wrench is certified to have been calibrated prior to shipment to the accuracy of 3 in the clockwise direction and 6 in the counterclockwise direction Copyright 2019 05 07 ...

Reviews: