28
OPERA
TION
Ensure that the self flush valve is closed at the end
of this function, or before loading or circulating asphalt
to eliminate chances of inducing asphalt into the self
flush fuel tank.
Handspraying
Before spraying, place the valves in position for
handspray.
WARNING
To prevent burns from hot asphalt when
handspraying: Hold the handspray gun in
proper position and watch for other people.
WARNING
To prevent burns: Always wear eye protection,
long sleeve shirt, insulated gloves, boots, and
long pants outside the boots when working
around the distributor.
At the rear panel, turn the master power switch off.
In the cab
Turn the “Rotary Actuator” knob to the “Circulate
in Tank” position.
Turn the spray bar switch “off”.
Turn the “Power” switch “On”.
At the rear panel, turn the Master Power switch on
and place the “Suction Valve” switch in the “Open”
position.
Adjust the asphalt pump speed to 80 GPM using the
“Circulation Rate” switch in the cab, or set the “Pump
Control” switch to “rear” and adjust the pump speed
with the “Pump Control” knob. Remember, the GPM
reading is only available in the cab of the distributor.
CAUTION
When using rear pump control, engine RPM
changes will affect asphalt pump speed
Turn the handspray valve on the spray wand 90 de-
grees to spray.
Adjust the handspray pressure with the “Return”
valve. Turn the “Return” valve clockwise to increase
the handspray pressure. Do not close the “Return” valve
completely as this will cause the asphalt to dead head
into the handspray hose when the handspray wand is
shut off.
If the “Return” valve is approaching the completely
closed position and pressure in the wand is insufficient,
turn the “Return” valve counter clockwise and increase
the asphalt pump flow rate.
When finished hand spraying suck back the hand-
spray system.
Figure 10. Valve Positions for Handspray.
Suck
Back
Off
Hand
Spray
Hand Spray Valve Positions
4 Way Valve
Circulate in Tank
Suction Valve
Open
Suck Back
Valve
Closed
Handspray
Valve
Handspray
Suckback
Control Cylinder
Closed
Transfer Valve
Closed
Hand Spray
Valve
Closed
Transfer Line
Suck Back
Valve
Closed
Return Valve
Partially Open
Flush Valve
Closed
Butterfly Valve
Cylinder Extended
Butterfly Valve
Open
Summary of Contents for Black-Topper Shooter II
Page 3: ...2 ...