Aventics Valve Diagnostics Cont'd
Meaning of the diagnostic LED’S
Designation Color
State
Meaning
IO/Diag(16)
Green
Illuminated The configuration is (OK) and the backplane
communication is (OK)
Green
Flashes
Incorrect CAN address
Red
Illuminated Diagnostic message from module present
Red
Flashes
Configuration or backplane communication error
Run(17)
Green
Illuminated
Operation display, Module is in the (Operational) State
Green
Flashes (Slow) Module is in (Pre-Operational) State-Slave is
waiting for start signal from CAN Master
Green
Flashes (Once) Module is in the (Stopped) State
Green
Off
Module is in the (Initializing) State
Error(18)
Red
Illuminated
Module is in the (BUS Off / Non Active) State
Red
Flashes (Once) Module is in the (Error Passive) State-at least one
error counter has reached/exceeded limit.
Red
Flashes (Twice) Module is in the (Error Control Event) State
Monitoring error has occurred
Red
Flashes (Three) Module is in (Sync Error) State-Transmission
interrupted or out of prescribed allowance
None(19)
None
None
Not assigned