BGA ETA-H15 OPERATION MANUAL
Page11
Melting temperature of solder. At this temperature, the solder starts to melt down and turn into liquid.
S1
Heating time rising from T1 to T2. User can set the value in the range of 0~300s.
S2
Heating time rising from T2 to T3. User can set the value in the range of 0~300s.
S3
Prolonged heating time (Heat preservation time) after the temperature reach T3, and user can also set the
value in the range of 0~999s.
Unit
It’s able to set the unit of display temperature during work flow. In parameter modifying, use
UP
and DOWN
keys to set the value of it.
Sensor
It is used for choosing the system’s sensor type. Users can also choose K type sensor used for measuring
temperature, besides system’s IR sensor. The signal of chosen sensor will be displayed and used for process
controlling. In parameter modifying, use the
UP
and DOWN key to set the value.
Password
It is used for setting password. It is designed for preventing the equipment unnecessary or non-authorized
change. When it is set to “000”, the password protecting is useless. The password is used for all flows and it
can be useful and useless in each flow. The system requires inputting correct password before any change.
Using of password refer to
A
item.
For instance: Modify parameter of flow one and make T1=130℃, S1=70s, T2=160℃, S2=50s,
TB=130℃. (Flow one has been selected)
Press MENU Press MENU
Press MENU rotate MENU
Press OK rotate MENU
password: ***
select: 1
_
T1: 110
℃
S1: 060s
T1: 110
℃
S1: 060s
T1: 110
℃
S1: 060s
T1: 130
℃
S1: 060s
_
T1: 130
℃
S1: 060s