EN 16
What you should be aware of
Safety instructions for installation
•
The electrical connection must comply with national and local
regulations.
• The appliance must always be earthed.
•
This appliance should only be connected by a registered electrician.
• The hob needs to be set correctly in accordance with the connection.
Hi = multi phase connection (2 x 16A); Lo = 1 phase connection
(1 x 16A).
•
For connecting, use an approved cable (for example type HO7RR)
with the correct cable diameters appropriate for the connection.
The cable casing should be of rubber.
•
The connection cable must hang freely and should not be fed
through a drawer.
•
If you want to make a fixed connection, make sure that a multi-
polar switch with a contact separation of at least 3 mm is fitted in
the supply line.
• To avoid dangerous situations resulting from any damage to the
connecting cable, this should only be replaced by the manufacturer,
the manufacturer's service organisation or by qualified persons.
•
The worktop into which the hob is fitted should be flat.
•
The walls and the worktop around the appliance must be made of
heat-resistant (> 85°C) material. Even if the appliance itself does
not get hot, the heat from a hot pan could cause discolouration or
distortion to the wall or worktop.
•
Damage caused by incorrect connection, incorrect use or incorrect
fitting in is not covered by the guarantee.
• The connection point, the wall socket and/or the plug must always
be accessible.
Space around the hob
Sufficient all-round clearance is essential to the safe use of the hob.
Check that there is sufficient clearance.
INSTALLATION
* 600 mm
cooker hood
cabinet
side wall
hob