EN 27
Please note!
After installation of the device, check whether the burners work properly.
The flame pattern should be regular and stable on the high setting, and
the burners must not go out on low.
Technical data
The data plate on the underside of the appliance indicates the total
nominal load, the required voltage and the frequency.
This appliance meets all relevant CE guidelines.
Connection
230V - 50Hz
Power output
2.67 kW
External dimensions (mm)
Width
600
Height
865-950
Depth
590/1000 with door open
Gas information
Burner
Gas
Operating
pressure mbar
Normal (1.65 kW)
G25
25
High (2.8 kW)
G25
25
Simmer (1 kW)
G25
25
Wok (4 kW)
G25
25
INSTALLATION