73
INST
ALLA
TION GUIDE
Space to be left free around the
appliance
Fitting the hob
Above a drawer or fixed decorative trim.
Above a 60 cm ETNA oven. Above an oven of
another make with casing cooling.
■
Ensure that there is a space of at least
10 mm between a drawer and the hob.
Take care that the drawer cannot put any
mechanical pressure on the connection
cable.
■
Make an opening in the side wall of the
kitchen cupboard for leading the
connection cable through (for building-in
in combination with an oven). This is
necessary when the plug can no longer be
reached after building in. Wall socket and
plug must be accessible at all times.
■
A certain height under the worktop is
necessary if the hob is installed above an
oven. This height under the worktop
depends on the following:
-
Worktop thickness;
-
Installed height of the hob (see table);
-
Height of oven at highest point (not
including the operating panel).
The required height under the worktop is
the height of the oven at the highest point
plus the installed height of the hob less the
worktop thickness.
min. 600 mm
min. 650 mm
min. 450 mm
min. 40 mm
cooker hood
cabinet
side wall
Ceramic hob
min. 40 mm
Height of oven
at highest point
Worktop thickness
Installed height
of the hob
Height under
the worktop
72
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the
neutral is 230 V a.c.
Install connecting bridges between the
connection points 4-5. Uw groepen moeten
afgezekerd zijn met minimaal 16 A (3x). The
connecting power cable must have a minimum
core cross section of 2,5 mm
2
.
You can use the bridges provided on the
connecting block to make the required
interconnections as indicated in the preceding
illustrations. How to install the bridges is
indicated in the junction box cover and in the
illustration below. The bridges should not be
placed immediately on top of the connecting
wires, but between the screw-head and the
clamp around the connecting wire.
Secure the cable with the strain relief and
close the cover.
Cut opening in worktop
Saw the opening in the worktop. This should
be done very accurately (see table). Also saw
out any partitions that may be present.
The distance from the saw line to the rear wall
and/or side wall is indicated in the table.
Table
INST
ALLA
TION GUIDE
right front
left front
left rear
right rear
appliance
internal
Type of hob
T200
Appliance width x depth
600 x 510 mm
x
Installation height from top of worktop
48 mm
Cut out dimensions width x depth
560 x 490 mm
x
Distance from saw line to rear wall
50 mm
Distance from saw line to side wall
60 mm