INSTALLATION INSTRUCTIONS
The Wall Vault™ is specifically designed to be mounted into a standard residential wall with at least 2x4
construction and wall studs of at least sixteen (16) inches on center apart. It is recommended to use an
industrial grade stud finder to locate studs and ensure the wall void is free of other obstructions (ie. water
pipes, electrical conduit, etc.).
Installing the Wall Vault™
(Please Review Warnings & Recommendations Section)
1.
Locate desired mounting location (please refer to IMPORTANT NOTICE section on pg. 4) (See Figure 1)
2.
The insertable section of the Wall Vault™ is approximately 14” x 14”. It is recommended to allow a 1/8“
tolerance for each side of the Wall Vault™ making the hole size approximately 14.25” x 14.25“. Once
mounting location is determined, cut hole in wall accordingly. (Refer To Template) (See Figure 2)
3.
Carefully place vault in wall. Do not forcefully insert. Vault should slide into wall easily (See Figure 3)
4. Open
vault
door
A. Biometric Wall Vault™ (Model 20700)
a. Press the ‘*’ button located on the Touchpad (See Figure 4A)
b. Wait five (5) seconds until beep, green LED light will flash once
c. Press default code, 1 2 3 4 4 and ‘*’ button
* If the battery is dead, use emergency access key (refer to Operating Instructions)
B. Keypad Wall Vault™ (Model 20710)
a. Input pin (default is 1 2 3 4) and press ‘#’ (See Figure 4B)
* If the battery is dead, use emergency access key (refer to Operating Instructions)
5.
Vault door will drop (See Figure 5)
6.
Locate the 4 mounting tabs, 2 on each side of vault walls (See Figure 6)
7.
Mark holes for pre-drilling (See Figure 7)
8.
Remove vault and pre-drill holes with a 1/8” bit
9.
Reinsert vault and screw bolts and washers into pre-drilled holes through vault tabs (See Figure 8)
Biometric Wall Vault™ Trickle Charge Option:
(Model 20700) See Important Note Below
Please consult a licensed electrician for questions.
Important: Terminal only accepts 12-14 VDC. DO NOT WIRE DIRECTLY TO TYPICAL HOUSE WIRING 110 VAC
1.
Locate terminal jack beneath sticker at top side of vault
2.
Wire to terminal a 12-14 VDC
3.
Terminal will accept non-specific polarity
7
8.ai 2/14/2005 11:28:37 AM