Superior Pro-Heat Programmable Thermostat User’s Manual
Model: 031530
The Pro-Heat thermostat is suitable for floor heating systems,
controlling the voltage of either a 120VAC or 240VAC.
I.
Main Functions and Features
Blue backlight, clear display
Independent keys, easy to operate
Can be controlled via sensors or time
Factory set with 4 programmed schedules for user’s
choice
Remote on/off control to connect to a home automation
system
Calculates the heating time which helps calculate the
energy consumption
Keyboard lock function
II.
Product Details & LCD Display
III.
Installation and Wiring
Installation
Installation must be carried out by a certified electrician
and must comply with national and local electrical
codes.
o
Open the keypad cover and
loosen the screw allowing for the
separation of the front module
from the power module.
o
Pull outward near the bottom of
the front module and lift off.
o
Find a location for the
thermostat in your home. It is
for indoor use only. Install the
thermostat at a height between
4 and 5 feet above the floor, or
on an inside wall. Direct
sunshine and heat appliances
should be avoided.
o
Turn off the power to the floor
warming system before doing
any electrical work.
o
A dedicated circuit is ideal for the installation of this
thermostat. If a dedicated circuit is not possible, make
sure there is enough load capacity on an existing circuit
to handle the addition of your floor warming system.
This circuit should NOT be wired in series with any
other device including other GFCIs.
o
The circuit breaker in the main circuit panel should be
15 amps maximum for a floor warming system totaling
12 amps or less. For a larger system up to 15 amps, use
a 20 amps maximum circuit breaker. NEVER exceed 15
amps on the thermostat.
o
Pull the power supply wiring in to this box, leaving
about 6 inches of wire.
o
Refer to your floor warming system. Pull the floor
sensor wire and the power lead wires from your floor
warming system up the wall
in to this box.
o
Mount the electrical panel.
CAUTION:
High Voltage—
Disconnect power supply
before servicing.
Do NOT use where exposed
to rain.
Mount this control only to a
grounded metallic box or a
nonmetallic box.
Wiring
Line1 (
L
) and Line2 (
N
) (Line
120VAC/240VAC) and Load1
(
LOUT
) and Load2 (
NOUT
)
o
Connect
L
and
N
to the power supply with the wire
nuts. Gently tug on the wires to make sure there is no
failure in the connection. Consider wrapping the wire
nuts with electrical tape to secure the wire connection
tightly.
o
Connect
LOUT
and
NOUT
to the floor warming system
lead wires with the wire nuts. Gently tug on the wires
to make sure there is no failure in the connection.
Consider wrapping the wire nuts with electrical tape to
secure the wire connection tightly.
o
Connect the house ground wire to the green lead wire
of your floor warming system.
o
Insert the ends of the floor sensor in to the terminal 1
and 2 and tighten the screws. The blue wire should be
secured in terminal 1 and the red wire should be
secured in terminal 2.
Note: Before continuing, make sure your power supply
voltage matches the voltage rating of your floor
warming system. Connecting 240VAC to a 120VAC
floor warming system will cause overheating and
damage to the system and may damage the controller,
other wiring, floor coverings, etc.
IV.
Parameter Setup
On/Off Switch
Found on the side of the thermostat. The switch must be
placed in the “
on
” position to allow any of the
programming to function. When in the “
off
” position, the
system will not heat and the keys will not function.
Setting the Date and Time
o
Press and hold the
Day/Time
button
until the
hour
begins to flash. Press
▼
or
▲
to adjust the hour.
o
Press the
Day/Time
button again and
the
minutes
will begin to flash. Press
▼
or
▲
to adjust the minutes.
o
Press the
Day/Time
button again and the
day of the
week
along the top will flash. Press
▼
or
▲
to adjust
the day of the week.
o
Press the
Hold/Return
button once more and your
settings will be stored.
Switching Between °F/12 h and °C/24h Format
o
Press and hold the
Options
button.
°F and 12 h
will show
on the display.
o
Press
▼
or
▲
to toggle
between
°F and 12 h
and
°C
and 24h
.
o
Press the
Hold/Return
button to store your settings.
Setting Your Heating Schedule
There are four factory set
schedules you can use,
designated P1, P2, P3, and P4.
1
2
3