background image

DIAGNOSTICS AND MAINTENANCE 

DOC_DEV_XS_Setup guide_C 

 

page 67

 

 

The summary table shows for each SHDSL line:  

If it is connected or not 
The data rate 
The line attenuation 
The SNR margin 

The number of erroneous seconds 
The number of disconnections 

 
 

To diagnose a malfunction of an SHDSL link, 

 

Select the SHDSL link

 

 

Click 

Show

.

 

 
The detailed status of the link is displayed. 
 

 

 
 

 

Summary of Contents for XLAN+ Series

Page 1: ...DOC_DEV_XS_Setup guide_C XSLAN XSLAN XSMIL SHDSL Switch _________________ SETUP GUIDE _________________ ...

Page 2: ...tup guide_C The XSLAN XSLAN and XSMIL SHDSL switches are designed and manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL 33 0 4 76 04 20 05 E mail hotline etictelecom com web www etictelecom com ...

Page 3: ...13 2 1 Principle of operation 13 2 2 Connection profiles 14 3 Setting up a link using one twisted pair 15 3 1 Set up steps 16 3 2 Step 1 SHDSL connection setup 16 3 3 Step 2 SHDSL test and set up adjustment 18 4 Setting up a link using 2 3 or 4 twisted pairs 20 5 Advanced setting up of an SHDSL link 21 6 RSTP 26 6 1 Overview 26 6 2 Set up 27 7 Fail safe ring 30 8 Loop VPN 32 9 VLAN 34 9 1 Overview...

Page 4: ...3 16 7 Telnet gateway 64 DIAGNOSTICS AND MAINTENANCE 65 1 Visual diagnostic 65 2 Log 65 3 Link quality measurement 66 4 SHDSL statistics 68 5 Gateways status 69 6 PING tool 70 7 Saving and loading a configuration file 71 8 Updating the firmware 73 ANNEX 1 SNMP MIB 75 1 Purpose of the document 75 2 Accessible OIDs and MIBs 75 2 1 Supported MIBs 75 2 2 Network interface indexes 76 2 3 Querying the M...

Page 5: ...Ethernet switch XSLAN 4xxx Industrial grade 4 SHDSL ports Ethernet switch XSMIL 4200 Military grade 4 SHDSL ports Ethernet switch In this document the name XS refers to both XSLAN XSLAN and XSMIL products 2 Main features of the XS family The XS family of SHDSL switches enables the connection of remote Ethernet networks with one two or four twisted pairs depending on model Key features 5 7 Mb s ove...

Page 6: ......

Page 7: ... the PC directly to the LAN interface of the SHDSL switch Subsequent changes can be made remotely Restoring the factory IP address The factory IP address 192 168 0 128 can be restored see the User guide of the product Restricted access to the administration server If you do not have access to the administration server it is probably that access has been restricted for security reasons or for other...

Page 8: ... web browser Launch the web browser and then enter the IP address of the XS 192 168 0 128 The Home page of the administration server is displayed Note Access to the administration server is not protected when configuring the XS for the first time 1 3 Changing the configuration later Thereafter the XS administration server is accessible from the Ethernet interface or remotely through the SHDSL line...

Page 9: ...ote If the IP address of the XS is unknown the software tool EticFinder can be used This software detects all ETIC branded products on a local network After starting the software click on the Search button and when the product list is displayed double click on the product address to access the html server 3 Restoring the factory settings To restore the factory settings using the push button Power ...

Page 10: ...tion steps To configure the product we advise to proceed as follows Set up the LAN interface Set up the SHDSL connections Set up the RSTP or failsafe ring redundancy protocol Set up VLAN Set up SNMP Set up QoS Set up the routing functions Set up the serial gateways ...

Page 11: ...his is the IP address assigned to the Ethernet interface of the XS on the local network This is the IP address of the administration server and the serial gateways Factory value 192 168 0 128 Netmask The netmask defines the local network size and which IP address belongs to that network Factory value 255 255 255 0 Default gateway This is the IP address of the default router on the local network ...

Page 12: ...The XS acts as a managed switch However if this box is checked the XS provides basic IP router features between two interfaces LAN Ethernet 10 100BT ports and SHDSL ports The Ethernet ports are considered as a single interface SHDSL ports 1 to 4 depending on model are also considered as a single interface The XS must have two IP addresses The one previously defined only applies to LAN Ethernet por...

Page 13: ...ge to STU R mode if it detects the presence of a STU C on the remote side Thus two XS configured both in STU C will find a way to connect One of the two will switch to STU R The STU C initiates the connection and measure the received signal level and the noise level and calculates the signal to noise ratio The longer the distance and the higher the noise level over the line the smaller the SNR rat...

Page 14: ...ta rate compliant to the EFM standard up to 5 6 Mb s The SNR ratio margin is high the date rate is low and the risk of disconnection is low in case of any disturbance The duration to establish the connection is longer typically 3 minutes and may take up to 5 minutes This profile is suitable for medium to very noisy lines or on cables not dedicated to the transmission such as cables with a large di...

Page 15: ...t link on a twisted pair Either between two XS as in the diagram below Or between two XS in case of a daisy chain or a ring network as in the diagram below Or between an XS used as a concentrator and several single port XS as in the diagram below STU R 1 twisted pair STU C Port 2 STU R Port 2 STU R Port 1 STU C Port 1 STU C STU R Port 4 STU C ...

Page 16: ...n a connection profile to the other XS STU C Standard or STU C Endurance or STU C Performance Step 2 SHDSL test and set up adjustment 3 2 Step 1 SHDSL connection setup Setting up the first XS In the menu choose Setup Ethernet switching SHDSL ports Tick the Enable SHDSL1 or 2 or 3 or 4 depending on the case checkbox Assign the STU R Auto profile Click Save ...

Page 17: ... 17 Setting up the other XS In the menu choose Setup Ethernet switching SHDSL ports Tick the Enable SHDSL1 or 2 or 3 or 4 depending on the case checkbox Assign the STU C Standard or STU C Performance or STU C Endurance profile Click Save ...

Page 18: ...onger time with other profiles The SHDSLx LEDs attached to each port displays the state of the connection as described in the table below State of the connection SHDSL LED The other XSLAN was not detected for example when the line is not connected Blinking 0 1 s ON 2 s OFF Data rate negotiation Blinking 0 3 s ON 0 3 s OFF Connected Steady on Traffic on the link Flashing Once connected choose Diagn...

Page 19: ...ain the connection Once all the SHDSL connection run correctly send periodically a PING from a PC to a remote XS or device to check that no error occurs Remark one can use the PING tool included in the XS Diagnostics Tools PING If despite these changes the quality is insufficient or if disconnections occur or if the connection is not established check the line Check that each conductor of the line...

Page 20: ...h four SHDSL ports can establish a multiplexed link with up to four pairs the data rate is approximately quadrupled up to 22 Mb s or even 40 Mb s up to 1 Km Setting up The parameters are set in the same way as for Setting up a link using one twisted pair Assign the STU R Auto profile to all SHDSL port of the first XS Assign a connection profile to all SHDSL port of the other XS STU C Standard or S...

Page 21: ...rce the modulation The modified profile is added to the five profiles To add a new connection profile In the menu choose Setup Ethernet commutation SHDSL ports Tick the Show advanced parameters checkbox Select one of the existing profiles Click Copy and edit The corresponding window is displayed it allows to tune the below parameters Click Save the new profile is added in the profiles list and it ...

Page 22: ...ates the connection and negotiates the conditions STU R The wait for a connection Rate adaptation to the line Rate adaptation system Possible values Line probing Quick adaptation is approximate Dichotomic search Best adaptation for the line but longer connection time Fixed data rate Fastest connection time but no adaptation performed Line probing mode The line is probed briefly to estimate the att...

Page 23: ...mpts to connect with this alternative margin The value must be higher than the previous which will result in a connection at a lower data rate Possible values 10 to 21dB Dichotomic search The XS successively performs several connections at different rates until the connection satisfies the requested criteria of bit rate and signal to noise ratio margin Bisect steps The higher the number the more a...

Page 24: ...hen it can attempt the direct reconnection at the same rate as before which significantly reduces the link downtime Possible values 0 to 120 s 0 means unused Advanced settings Annex Possible values Annex A or Annex B Default value Annex A PAM constellation The PAM constellation defines the modulation used Possible values Auto PAM16 PAM32 Default value Auto Capacity list The capacity list exchanged...

Page 25: ... established at a higher data rate Minimum SNR margin for renegociation dB Renegotiation causes a disconnection and therefore a loss of service during the time of recovery This is why the renegotiation should be attempted only if the margin increased very significantly enabling a significant increase in throughput Minimum duration before renegociation hours Renegotiation causes a disconnection and...

Page 26: ...bridge to bridge to ensure propagation of the information in the network When a bridge receives BPDUs from root from 2 of its ports meaning there is a loop in the network it will only forward the best one and block the port where the others were received When a link fails BPDU are not received anymore by the bridge and it will enable previously blocked ports in response RSTP supersedes the old STP...

Page 27: ...SL ports parameters General parameters Bridge priority This value is prepended to the MAC address of the bridge to form the bridge ID This is used by the network to choose which bridge will become the root of the spanning tree The root is the bridge with the lowest bridge ID Hello time The Hello time is the delay between 2 consecutive BPDU sent by a bridge It must be the same for all bridges in th...

Page 28: ...er because it becomes unnecessary and increases the convergence time Maximum age When the STP root transmits a BPDU the information contained in it is forwarded from bridge to bridge At each retransmission a bridge adds 1 to a counter in the data When this counter exceeds the Max Age value the BPDU is not forwarded Note 1 This acts like the TTL in IP packets Note 2 This value must be large enough ...

Page 29: ...te link versus a low data rate link A high data rate link usually has a low cost Recommended values SHDSL port 200 000 000 Ethernet 100 Mb s port 200 000 Edge port An Edge port is a port located on the border of the network with no bridge attached to it like for instance an industrial device or a PC BPDU are not transmitted to that kind of port moreover that kind of port cannot be blocked P2P port...

Page 30: ...t loop and leave the other in forwarding mode When a device or a link fails in the SHDSL ring the second port will be enabled allowing to reach all the devices in the ring Remark In this mode LAN ports do not participate in the algorithm only the SHDSL ports are used The advantages of that solution is that the failure detection delay and the recovery delay is only a few seconds One second if the r...

Page 31: ...afe ring mode Tick the Ring master checkbox Select the default blocked port Click Save Other switches configuration In the menu choose Setup Ethernet switching RSTP Fail safe ring Select the Fail safe ring mode Leave the Ring master box unchecked Click Save ...

Page 32: ... RSTP protocol redundancy may be provided thanks to that VPN One XS must be configured as a VPN server mode and must be accessible via a fixed IP address across the WAN The other XS must be configured as a VPN client The VPN is established on the Ethernet LAN1 port of the XS switch and that port becomes a WAN port with its own IP address This Ethernet port must be connected to the WAN access route...

Page 33: ...d as a VPN client VPN server IP address When the XS is the VPN client the IP address to reach the VPN server switch must be defined This IP address is not necessarily the one assigned to the VPN server XS in the Local WAN IP Address parameter if the VPN goes through routers with Network Address Translation NAT Port TCP or UDP port number of the VPN Protocol TCP or UDP protocol of the VPN Pre share...

Page 34: ...e can be removed by the Ethernet switch before being transmitted to the Ethernet device or can be transmitted tagged to the device The switch filters the Ethernet frames according to their VLAN ID When they come into the switch on an Ethernet port Ethernet frames are tagged with the VLAN ID assigned to that Ethernet port When it is received by the switch a tagged Ethernet frame can only come out t...

Page 35: ... through an Ethernet port or remotely through the line One Ethernet port at least belongs to the same VLAN as the administration html server of the XS In the menu choose Setup Ethernet Switching VLAN Tick the Enable VLAN management box The page allows you to set the output policy the input policy and the VLAN ID of the administration server and the serial gateways ...

Page 36: ...its the switch on the LAN1 port tagged The LAN2 port is registered on VLAN 12 The frames that belongs to the VLAN exits the switch on the LAN2 port untagged Lan3 and LAN4 ports don t belong to any VLAN not used The SHSDL ports are registered to all VLANs All frames are transmitted on the SHDSL network tagged Egress policy LAN1 LAN2 LAN3 LAN4 SHDSL VLAN 4 Yes tagged No No No Yes tagged VLAN 5 Yes t...

Page 37: ... exit the port untagged Frames exit the port unmodified Ethernet frames belonging to this VLAN can exit on LAN1 port or 2 or 3 or 4 Frames exit the port unmodified tagged or untagged Port does not belong to this VLAN Ethernet frames belonging to this VLAN can not exit on LAN1 port or 2 or 3 or 4 SHDSL Egress policy Frames exit the port tagged Ethernet frames belonging to this VLAN can exit on SHDS...

Page 38: ... No No No Yes tagged VLAN 12 No Yes untagged No No Yes tagged The table hereafter defines the ingress policy LAN1 LAN2 LAN3 LAN4 SHDSL VLAN ID 4 12 0 0 12 Accept all frames Refuse a frame not belonging to a configured VLAN X Refuse a frame not belonging to a VLAN associated to the port X X X X LAN1 Only frames tagged with ID 4 or 5 can enter through this port Untagged frames are assigned to VLAN 4...

Page 39: ...not belonging to a VLAN associated to the port An untagged frame entering the Ethernet port will belong to the VLAN of this port Tagged frames entering the Ethernet port are only accepted if their VLAN ID is one of the registered VLAN or that port see Egress policy Frames tagged with another VLAN ID are denied LAN1 VLAN ID or LAN2 or LAN3 or LAN4 or SHDSL This is the VLAN ID assigned to an untagge...

Page 40: ...ll check whether or not it should forward or block a given traffic on a given port When there is no multicast router to query the network one of the IGMP snooping enabled switch can do the queries The device with the lowest IP address is elected as the querier for the network 10 2 Setting up the IGMP snooping function In the menu choose Setup Ethernet and switching IGMP snooping Tick the Enable IG...

Page 41: ...of erroneous seconds during the last quarter of hour SHDSL links Number of erroneous seconds during the last 24 hours RSTP ports status blocked learning forwarding RSTP bridge parameters bridge ID priority MAC root MAC addresses data base The XS is also able to send SNMP traps when the following events occur Ethernet 10 100 BT port connection Ethernet 10 100 BT port disconnection SHDSL connection ...

Page 42: ...ond SNMP manager IP address Enter the IP address of the second SNMP manager where to send SNMP traps Community name Enter the name of the community to which the product belongs System name The system name is the name of the product XSLAN 2400 for example System location Enter a string which identifies the location where the product is installed ...

Page 43: ...tup Alarms SNMP traps Select the traps which must be transmitted by the product Product startup Cold start Fail safe ring up LinkUp Fail safe ring broken LinkDown Gateway restarted WarmStart RawTCP server gateway connected LinkUp RawTCP server gateway disconnected LinkDown Link status change ...

Page 44: ...time server at the other end of the link Equipments connected to the LAN ports of the XS are synchronized locally This allows not to overload the low data rate SHDSL link by many NTP requests 12 2 Setting up the NTP client In the menu choose Setup System Date and time settings NTP Tick the Sync the clock using timeservers checkbox NTP Servers Enter the IP address of the NTP time server If there ar...

Page 45: ...ined traffic is assigned to the class Default The Platinum class has the highest priority That traffic is routed first whatever the traffic in the other classes Classes Gold Silver Bronze share the available bandwidth Exemple Minimum bandwidth Maximum bandwidth of the whole bandwidth of the whole bandwidth Gold 50 80 Silver 30 80 Bronze 15 80 Default 5 Unlimited Total 60 Once the traffic of one of...

Page 46: ...ssigned by the XS DSCP value DiffServ classes supported by the XS Platinum EF 46 EF Gold AF11 10 CS1 AF11 AF12 AF13 Silver AF21 18 CS2 AF21 AF22 AF23 Bronze AF31 26 CS3 AF31 AF32 AF33 Default BE 0 BE 13 2 Basic configuration In the menu choose Setup IP protocol and routing QoS DiffServ Tick the Enable QoS checkbox ...

Page 47: ...device or this group of devices Enter an IP address to specify a single host for instance 192 168 10 12 or a range of IP addresses and a netmask for instance 192 168 10 0 255 255 255 0 Click Save Step 2 Optionally set other services In the menu choose Setup System Service list Click Add Give a name for this service Define a protocol and a port number for that service Click Save ...

Page 48: ... protocol and routing QoS DiffServ Tick the Enable QoS checkbox Assign a minimum and a maximum bandwidth to each class Gold Silver Bronze Click Save Step 4 Classify the traffic Under the traffic classification table click Add Assign a device and a service to a class Platinum Gold Silver Bronze Click Save ...

Page 49: ...SETUP DOC_DEV_XS_Setup guide_C page 49 ...

Page 50: ...es located in a different IP network the XS usually send the IP frames to its default gateway However for more complex situation it is possible to create static routes or use a routing protocol 14 2 Static routes To create a static route In the menu choose Setup IP protocol and routing Static routes Click Add Enter the destination IP address the netmask the gateway address used for this destinatio...

Page 51: ...uter mode is enabled or not 14 4 OSPF protocol The OSPF protocol performs the same function as RIP but is used on more complex network configuration The XS supports OSPF but the configuration is done via SSH command line This is an advanced operating mode which allows the XS to behave as a very flexible and sophisticated router For example it is possible to bridge any Ethernet port with any SHDSL ...

Page 52: ...larms See SNMP chapter 15 2 Digital output The digital output can switch OFF in case of one of these events Port SHDSL 1 disconnected Port SHDSL 2 disconnected Port SHDSL 1or 2 disconnected Fail safe ring broken Only available on XS with more than one SHDSL port ...

Page 53: ...etwork to transport serial data between two or several serial devices or directly with devices connected to the Ethernet network Communication between serial devices Communication between a serial device and a PC via a COM port emulation software Communication between serial devices and a PC software application able to encapsulate the serial data into UDP or TCP like a Modbus TCP software applica...

Page 54: ...o a Modbus slave device connected to the same serial network A Modbus slave device is a device connected to a serial asynchronous link and able to reply to Modbus requests connected to the same serial network Modbus address An address between 0 and 254 assigned to each participant to a Modbus network Remark the Modbus address must not be confused with the IP address of a Modbus device 16 2 2 Selec...

Page 55: ...smit the request to the corresponding IP address In addition the Modbus address field of the Modbus TCP frame is set to A The mapping table can contain 32 lines allowing a Modbus master to address 32 servers on the IP network To configure the gateway In the menu choose Setup IP RS gateways Modbus Modbus client Tick the Enable Modbus client checkbox Configure the following parameters COM port Selec...

Page 56: ...e time the gateway will wait before disconnecting the TCP link if no characters are detected TCP port Set the port number the gateway has to use The default Modbus TCP port is 502 Modbus slaves The table allow the mapping of a Modbus slave address to an IP address ...

Page 57: ...code and transmit the request on the serial link The Modbus slave address of the request is Either the address contained in the Modbus TCP address field in this case several slaves can be addressed on the serial link Or a fixed address configured in the gateway see below in this case only one slave can be addressed on the serial link Warning Several TCP Modbus client can send requests to the slave...

Page 58: ... have to wait between a received character of a Modbus answer packet and the following character of the same packet Modbus slave address If the value 0 is selected the gateway uses the Modbus address specified by the Modbus TCP client to address the Modbus slave on the serial link up to 32 slaves can be addressed on the serial link If a particular value is selected 1 to 255 the gateway sends all r...

Page 59: ...ve buffer size Set up the maximum length of an asynchronous string the gateway will store before transmitting it to the IP network RS end frame timeout Set up the delay the gateway will wait before declaring complete a string received from the asynchronous device Once declared complete the gateway will transmit the string to the IP network TCP idle Timeout Set the time the gateway will wait before...

Page 60: ...he asynchronous serial link Receive buffer size Set up the maximum length of an asynchronous string the gateway will store before transmitting it to the IP network RS end frame timeout Set up the delay the gateway will wait before declaring complete a string received from the asynchronous device Once declared complete the gateway will transmit the string to the IP network TCP idle Timeout Set the ...

Page 61: ...Tick the Enable checkbox Configure the following parameters Bitrate Parity Data stop bits Allow to set the bitrate and the format of the asynchronous serial link Receive buffer size Set up the maximum length of an asynchronous string the gateway will store before transmitting it to the IP network RS end frame timeout Set up the delay the gateway will wait before declaring complete a string receive...

Page 62: ...re the following parameters Bitrate Parity Data stop bits Allow to set the bitrate and the format of the asynchronous serial link Receive buffer size Set up the maximum length of an asynchronous string the gateway will store before transmitting it to the IP network RS end frame timeout Set up the delay the gateway will wait before declaring complete a string received from the asynchronous device O...

Page 63: ... Tick the Enable checkbox Configure the following parameters COM port Select the serial link 1 or 2 of the product Bitrate Parity Data stop bits Allow to set the bitrate and the format of the asynchronous serial link Xway address Gateway address in the Xway network TCP idle Timeout Set the time the gateway will wait before disconnecting the TCP link if no characters are detected Unitelway slaves M...

Page 64: ...to the RFC2217 standard To configure the gateway In the menu choose Setup IP RS gateways Telnet Tick the Enable checkbox Configure the following parameters COM port Select the serial link 1 or 2 of the product Bitrate Parity Data stop bits Allow to set the bitrate and the format of the asynchronous serial link TCP idle Timeout Set the time the gateway will wait before disconnecting the TCP link if...

Page 65: ...n of the product Then the LED turns green and blinks for 30 seconds then becomes steady green when the product is ready If the LED remains red after that delay the product is probably faulty please contact the hotline 2 Log The log displays the last three hundred time stamped events including the SHDSL connections and disconnections To access the log In the menu choose Diagnostic Log ...

Page 66: ...ances on the line 2 The link loss number The number of disconnections is a good indicator of the quality of the link On a link that works fine disconnections must be very rare and should only happen during a thunderstorm or an electromagnetic disturbance 3 Error rate of the link The number of errored seconds gives the error rate of the link When a link is working well the number of erroneous secon...

Page 67: ...hows for each SHDSL line If it is connected or not The data rate The line attenuation The SNR margin The number of erroneous seconds The number of disconnections To diagnose a malfunction of an SHDSL link Select the SHDSL link Click Show The detailed status of the link is displayed ...

Page 68: ...period of operation This is a set of counters indicating the link quality for every second similarly to the G821 standard Furthermore an hour by hour history of these counters can be used to correlate transmission defects with other events such as starting a motor and this to a depth of 15 days To access the SHDS statistics In the menu choose Diagnostics Statistics SHDSL counters ...

Page 69: ...cess the status of the gateways In the menu choose Diagnostics Gateways status This page displays the current settings of the gateways the number of bytes transmitted and the number of erroneous frames To analyze the RX and TX traffic on the serial link Click Serial data visualization ...

Page 70: ...DIAGNOSTICS AND MAINTENANCE Page 70 DOC_DEV_XS_Setup guide_C 6 PING tool This tool is used to send a PING frame from the product to a device on the network ...

Page 71: ...tion it is possible to save the running configuration to a file into the XS switch or export it to a PC as an editable file Conversely it is possible to load a configuration from the set of configurations stored in the XS switch or to import a configuration file stored in a PC In the menu choose Maintenance Configurations management To save the running configuration to a file into the XS switch In...

Page 72: ...iously stated Then select in the list the configuration to export and click Export to a PC To import a configuration file from a PC Click on Browse then select the file XXX txt to import Optionally change the name of the configuration and click Import from PC This configuration appears in the Configurations saved list Select this configuration in the list and click on Load this configuration it be...

Page 73: ...go up automatically after the update The update can be done in two ways If the updated firmware file is accessible from the user s PC it can be done directly with the browser using HTTP POST The update can also be done via a TFTP server there the updated firmware file has to be previously loaded To perform the firmware update using HTTP POST In the menu choose Maintenance Firmware update Select th...

Page 74: ......

Page 75: ...rted The SNMP agent functionality in the XS device is provided by the Net SNMP software package http www net snmp org A lot of common MIBs are implemented by this package In addition to these MIBs a few more specific MIBs are supported The common MIBs supported include the following RFC1213 MIB MIB 2 HOST RESOURCES MIB IF MIB IP MIB These will not be documented here unless there is something speci...

Page 76: ...lled on Windows using Cygwin To use them start a shell in a terminal window and test these commands This command will return all OIDs supported by the device mc ubuntu snmpwalk v1 c public 192 168 0 128 SNMPv2 MIB sysDescr 0 STRING ETIC Telecom XSLAN 4400 SHDSL switch firmware version v2 1 0 b2 SNMPv2 MIB sysObjectID 0 OID NET SNMP MIB netSnmpAgentOIDs 10 DISMAN EVENT MIB sysUpTimeInstance Timetic...

Page 77: ...orts 4 SHDSL 2BASE TL ports The interfaces are named lan1 lan2 lan3 lan4 for the 10 100BASE T interfaces from 1 to 4 sh1 sh2 sh3 sh4 for the SHDSL interfaces from 1 to 4 The br_lan and br_sh interfaces are Linux bridge interfaces They allow Ethernet bridging between the ports of the device In this table there are a few particularities OID IF MIB ifAdminStatus Display the administrative state of th...

Page 78: ...the other fields are invalid when this parameter value is not data OID HDSL2 SHDSL LINE MIB hdsl2ShdslEndpointCRCAnomalies CRC errors on the line OID HDSL2 SHDSL LINE MIB hdsl2ShdslEndpointLOSWS Seconds with one or more synchronization loss OID HDSL2 SHDSL LINE MIB hdsl2ShdslEndpointES Erroneous seconds A second is erroneous if there are one or several CRC errors or synchronization loss OID HDSL2 ...

Page 79: ...6 1 2 1 10 48 1 2 1 3 ifindex data rate of the SHDSL line It is recommended to monitor this OID if the chosen profile for the line is not a fixed datarate profile The other fields are not supported and are set to 0 3 3 3 Table HDSL2 SHDSL LINE MIB SpanConfProfileTable This table gives the list of the profiles defined for the SHDSL links configuration These informations are the same as the ones in ...

Page 80: ...edDiscards Not supported 3 4 3 OID BRIDGE MIB dot1dTp This oid gathers information on transparent bridges Ethernet switches 3 4 4 Table BRIDGE MIB dot1dTpFdbTable This table contains the MAC address table learned by the product OID dot1dFdbAddress MAC address learned by the switch OID dot1dFdbPort Which port to send a frame with the destination MAC address above OID dot1dFdbStatus the state of the...

Page 81: ...nk depending on the wire diameter and the distance These values are indicative in noise free environment Distance versus data rate through one pair Data rate 192Kb s 1 2Mb s 2 3Mb s 5 7 Mb s 6 7 Mb s 10 Mb s 12 Mb s 15 Mb s Distance Ø 0 9 mm 13 km 8 km 6 km 3 7 km 2 5 km 1 5 km 1 km 0 7 km Distance Ø 0 4 mm 7 km 4 km 3 km 2 km 1 3 km 0 9 km 0 6 km 0 4 km ...

Page 82: ......

Page 83: ...switch must be later than V1 3 2 1 Case 1 XSLAN is a STU R NTU Compatibility between a XSLAN switch and a XSLAN switch is guaranteed unconditionally The XSLAN switch must be configured with the STU C Standard profile or with a fixed data rate profile In this case the data rate must be less than or equal to 2304 Kb s 2 Case 2 XSLAN is a STU C LTU Compatibility between a XSLAN switch and a XSLAN swi...

Page 84: ...13 Chemin du Vieux Chêne 38240 Meylan France Tel 33 0 4 76 04 20 00 contact etictelecom com www etictelecom com ...

Reviews: