FPT-130 INSTALLATION MANUAL  |  

PART NO. 

25165

 REV 

F

TABLE OF CONTENTS

FPT 130 Overview.................................................................................... 2

Installation ................................................................................................ 3

Power Source and Load Connections................................................... 4

Temperature Sensor ................................................................................ 5

External Alarm .......................................................................................... 5

Dip Switches ............................................................................................. 6 

Operation ................................................................................................. 7

6SHFLƓFDWLRQV

 ........................................................................................... 9

Pilot Duty

The FPT 130 General Purpose Thermostat with GFEP cannot be used 

for Pilot Duty applications.

Devoir du pilote

Le thermostat à usage général FPT 130 avec GFEP ne peut pas être 

utilisé pour les applications Pilot Duty

Resistive Load Usage Only

This product is not for use with Inductive loads. Inductive loads may 

create nuisance tripping of the Ground–Fault Equipment Protection 

circuit.

Utilisation de charge résistive uniquement

Ce produit n’est pas destiné à être utilisé avec des charges inductives. 

Les charges inductives peuvent créer un déclenchement intempestif 

du circuit de protection de l’équipement contre les défauts à la terre.

Abnormal Odor or Smoke

In the event of smoke or a burning or abnormal odor, immediately 

interrupt power to the unit by turning off the circuit breaker protecting 

the unit.

MODEL FPT-130

TRACON

®

SINGLE–POINT FREEZE PROTECTION HEAT–TRACE CONTROL

Heat Tracing Sales        Mt. Airy, MD        (410) 795-2223        www.heattracingsales.com

Heat Tracing Sales        Mt. Airy, MD        (410) 795-2223        www.heattracingsales.com

Summary of Contents for Tracon FPT-130

Page 1: ...se with Inductive loads Inductive loads may create nuisance tripping of the Ground Fault Equipment Protection circuit Utilisation de charge r sistive uniquement Ce produit n est pas destin tre utilis...

Page 2: ...s la terre doivent toujours tre utilis s pour r duire les risques de choc et d incendie et prot ger l quipement Le c blage lectrique des l ments chauffants doit tre install conform ment aux exigences...

Page 3: ...round Fault Equipment Protection with manual and automatic test function Alarms for excess ground fault current low load current and temperature Alarms indicated with panel LED lights and relay contac...

Page 4: ...he hub to the conduit system before connecting the hub to the enclosure The unit comes with two installed liquid tight cable JODQGV 2QH RI WKHVH WWLQJV LV IRU WKH WHPSHUDWXUH VHQVRU cable and the othe...

Page 5: ...r provides dual Form A DPST contacts rated for heater loads up to 30 amps and 277 volts ac The dual contacts on the contactor are used to control both legs of the input power Line and Neutral Manual L...

Page 6: ...the COM terminal If the system needs a contact to close to signal an alarm or power off condition connect the other alarm relay lead to the NC Normally Closed terminal See Figure 6 If the system need...

Page 7: ...up If any DIP switch is changed while the unit is on then the power needs to be turned off and on again for the new setting to take effect FPT130 Thermistor Fault FPT130 Set Point GPT Heat On Fire Pro...

Page 8: ...tpoints except the 30 F 1 1 C setpoint For the 30 F 1 1 C setpoint the LOW TEMP alarm will indicate when the temperature drops to 28 F 2 2 C Blinking indicates sensor fault Blinking fast indicates Hig...

Page 9: ...KH EXWWRQ DW this point The unit will exit Manual Mode Note 7KH EOXH PD DVK IRU D FRXSOH RI VHFRQGV after releasing the red TEST RESET pushbutton The blue LED will indicate whether the LOW TEMP Alarm...

Page 10: ...e setpoint Low current alarm delay 5 s Ground fault limit current 30 mA Self Test Interval 24 h User Interfaces Pushbuttons Test Reset DIP switches Temperature setpoint Thermistor fault mode Fire prot...

Page 11: ...ion clearly on the outside of the shipping container so that it may be correctly processed upon receipt at Environmental Technology For more information about replacement parts or for a replacement Da...

Reviews: