background image

 

INSTALLATION MANUAL 

 

 

23033 Rev. A     04/10                                      http://www.networketi.com     Environmental Technology, Inc.     Page 2 of 4 

 

Step 1:  Turn off unit and remove plug. 

 

 

Step 2:  Remove top cover. 

 

For rack mount units, remove 12 screws. 

 

For wall mount units, remove 10 screws. 

 

 

Step 3:  Unscrew and remove the red and black 

wires.  If wires cannot easily be removed from 

ferrite core, cut cable tie and open core to remove 

wires.  Retain ferrite core for re-installation later in 

this procedure. 

 

 

Step 4:  Disconnect tubing from solenoid barbed 

fitting. 

 

 

Step 5:  Disconnect ground wire. 

 

 

Step 6:  Remove 4 mounting screws from the back 

of the unit (secure pump with other hand).  Set 4 

mounting screws and lock washers aside for use in 

re-installation. 

 

 

Step 7:  Remove screws, lock washers, and nuts 

from second mounting position and replace them in 

the holes where the original pump was located. 

 

 

Step 8:  Position Hargraves compressor over 

mounting holes and attach with screws, spacers, 

locking washers, and nuts. 

 

 

Step 9:  Route the red and black wires through 

ferrite core, secure core with cable tie, then re-

install the core in its original location as shown 

using the tie wrap mount. 

 