WarninG:
Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire,
or other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker. •
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
• Minimum 90°C supply conductors. • Risk of electrical shock. To reduce the possibility of serious injury, always take the proper precautions and unplug the fixture before moving or
cleaning.
nOTiCe:
Suitable for operation in ambient temperatures not exceeding 113°F/45°C. • Suitable for damp locations.
nOTiCe:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment
into an outlet on a circuit different from that to which the receiver is connected, and consult the dealer or an experienced radio/TV.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-eTI-SSLI (1-855-384-7754) www.eTiSSL.com
cONTINuOuS INSTALLATION
nOTe
:
Multiple light fixtures can be connected, up to a maximum of 8 Lights. Do not exceed 400 total watts for interconnected lights.
nOTe
:
If planning to continuously mount multiple fixtures using a single power source, feed the electrical wires from the electrical box through the center of the conduit and then through
the open knock out hole in the fixture.
nOTe
:
UL LISTED: CCN:FKAV/7 TYPE: 1/2 FOR THREADED COUPLER.
Punch out the knock out holes at each end of each fixture where the two fixtures
will connect.
Remove the end caps and open the lens of each fixture.
Insert a 7/8in. outer diameter fitting threaded coupler (not included) through both
open knock out holes. Secure the coupler with 2 threaded nuts (not included).
1
2
3
Insert one end of the jumper wires into the wire connectors from the first fixture, then
run jumper wires through the threaded coupler, and insert the other end into the wire
connectors from the next fixture and make the electrical connections.
Connect the two fixtures to the continuous mounting bracket using the thumb screws.
Close the lens. Reattach the end caps and make sure it is secure.
4
5
6
STeM MOuNTINg INSTALLATION
This section is for suspended mounted fixtures only.
Option Installation Accessory Kit Sold Separately
Installing contractor is responsible for determining best installation method for desired location and selecting the appropriate mounting hardware.
Threaded Coupler
Threaded Nut
H
H
B
D
H
A
Punch out the 2 knock out holes on the fixture that will be used for stem mounting.
Feed all the wires from the electrical box through the knock out hole.
Use the jumper wires to make the electrical connections from the electrical box to the
fixture:
• Black wire to black wire.
• White wire to white wire.
• Green wire to ground wire.
• If a 0-10v dimming circuit is available, connect purple wire to purple wire and gray
wire to gray wire.
Screw the ceiling plate and stem together, then feed the jumper wires through the
ceiling plate, stem, stem mounting kit bracket and into the electrical box. Reconnect
the terminal ground wire to the wire cover. Reattach the wire cover to the fixture and
make sure to tuck all of the wires inside the wire cover.
Use 2 screws (not included) to secure one of the stem mounting kit bracket (not
included) to the electrical box. Insert two plastic drywall anchors (not included) into
the ceiling and use 2 stem mounting kit screws (not included) to attach the remaining
stem mounting kit bracket (not included) to the ceiling. Make sure the ceiling plate,
stem, and stem mounting kit bracket are secure.
Insert one stem into one of the knock out holes in the fixture and secure the stem with
the stem mounting kit nut (not included). Repeat step with the remaining stem.
Close the lens cover.
Move the locks to the lock position on both ends of the fixture.
Reattach the end caps.
Restore power to the electrical box. Turn the light switch on to activate the fixture.
Turn the light switch off and back on again to activate the direct light only.
Turn the light switch off and back on again to activate the indirect light only.
nOTe
:
To change between light modes, the light switch has to be turned off and on
within 3 seconds.
5c
7c
9c
10c
8c
6c
11c
12c
13c
14c
P
O
N
Q
Knock out
hole
T
S
R
La versión española está en el