KL8800A User Manual 

www.ethink-spa.com                                                                6 

5.  At  the  initial  stage  of  each  filter  cycle,  all  other  loads  will  run  for  15  seconds  to  purify  the 

pipeline. Ozone will start to work after 15 seconds. 

    In order to prolong the lifetime of anti-virus system, ozone will work for 15 minutes and then 

idle for 15 minutes, and that cycle repeats. 

    When any surfing pump (or high speed pump) and blower is turned on, ozone will stop working. 
 

). Valid when A4=OFF: The temperature fine tuning (

This function is only effective 

for 

 temperature display

   

       

Press and hold “

” key to enter setting mode, and continuously press “

” key to 

go into temperature fine tuning mode(Fig. 9). At this moment, the user could click on “

 

or

 

” to change the temperature in small range, the ADJ(adjusting) range is -3~-7 .

 

        When ADJ=-3

 and the desired setting temperature is Tset=90 , 

then the heater will turn 

off after the water temperature reach to 91

, and the heater will automatically start to heat 

the water when the real temperature reach to 87 

(90

-3

=87

). 

        In the same way, when ADJ=-7

 and the desired setting temperature is Tset=90 , 

then the 

heater will turn off after the water temperature reach to 91

, and the heater will automatically 

start to heat the water when the real temperature reach to 83 

(90

-7

=83

). 

***Note*** 

      When  the  temperature  displayed  in  Celsius( ),  the temperature  control  range  is

  ±1 .

 This 

means that if the setting temperature is Tset=30 , when the temperature reach to 31 ,

 then 

the heater will turn off. When the temperature drop to 29 , the heater will automatically start to 

work again.   

   

                           

 

Fig. 9

The last time for filter cycle is 3hrs 

       

Fig. 10

Light brightness adjustment

 

)

Valid when A4=OFF: The light brightness adjustment 

     

Press and hold “

” key to enter setting mode, and continuously press “

” key to 

go  into  light  brightness  adjustment  mode(Fig.  10).  At  this  moment,  the  user  could  click  on 

 or

 

” to change the light brightness , the adjustment range is 3~252. 

Summary of Contents for KL8800A

Page 1: ...keys single color back lighting control panel Installation sketch 156 72mm AUX Fig 2 A8 OFF 8 keys single color back lighting control panel Installation sketch 183 66mm O3 AUX 1 2 1 3 2 4 AUX Fig 3 A...

Page 2: ...e and install 3 24 hours clock display and setting are used for circulating clean 4 Max allow heater thermostat power is 4 5KW with water temperature display and setting function 5 Max allow 3 surfing...

Page 3: ...the system will exit and save temperature settings and display current actual temperature of the SPA In order to ensure the precision of the detected temperature if no water flowing in the SPA within...

Page 4: ...it go within a second Working Mode 1 Three working modes Normal Mode Economy Mode and Filter Mode The working mode is only effective for circulation pump heater circulation filtration and anti virus...

Page 5: ...Fig 4 press key to set hours down button the adjustable range is 0 23 And press key to set minutes up button the adjustable range is 0 59 Fig 7 Current time is 12 34 Fig 8 Start time of filtration is...

Page 6: ...off after the water temperature reach to 91 and the heater will automatically start to heat the water when the real temperature reach to 87 90 3 87 In the same way when ADJ 7 and the desired setting...

Page 7: ...fing pump 1 works as a dual speed pump A6 OFF When the temperature appears abnormality or the sensor detected no water the heater and pump will stop working ON All HV loads can t be controlled by temp...

Page 8: ...g pumps will automatically turn off after 15 minutes When A5 ON the surfing pump 1 work as a dual speed pump The 1st time to press is to start high speed the 2nd time to press to turn off high speed a...

Page 9: ...rainage valve start The LCD is showing at this moment 4 2 There is a water level probe WATER1 to control the drainage the drainage will work for 1 hour and then automatically shut up when the probe de...

Page 10: ...and circulating pump are normal The water flow inside the heater is possibly too low It is sure that the volume of water flow inside the heater is not enough 1 Check whether the filter is blocked or...

Page 11: ...pump 10A 220 240VAC 3 Circulation pump 5A 220 240VAC Blower 5A 220 240VAC Replenishing valve 5W 12VDC Drainage valve or pump 5A 220 240VAC AUX 5A 220 240VAC LED Light 12W 12VAC or 12W 12VDC Ozone 8W 1...

Page 12: ...PUMP3 1A 6A HEAT1 CNHV ACL1 ACN ACL2 ACL2 HEAT2 ACL2 ACL2 ACL2 ACL2 ACL2 ACL2 P1L ACL2 VCC AUX P3 HT HT2 BL WOUT P2 P1 P1L HT68F13 SUB KEY CNHV KEY_DIS2 BTT 3A 2A A HT66F40 SENSOR OZONE B WIN LIGHT D...