KL8-3H-CAA6/KL8-3H-BAA6
www.ethink-spa.com
8
every time
,
working time is 30 seconds
,
ozone work for 15 minutes
,
15 minutes for clearance
。
Water surf PUMPS and BLOWER is turned on
,
ozone can not work
;
circulating pump is turned
off
,
the ozone can not work
。
13
、
the bottom light steps:
The first by
“
”
Key
,
to open the underwater lights
,
the color slowly changes
;
the second
time by
“
”
,
The color of the current fixed
;
the third time by
“
”
,
The closure of the
underwater lights
。
14
、
constant temperature heating steps:
1), in the pre-heating time to the pre-heating case opened or by
“
”
Key can be turned on the
heating system thermostat
。
2
)
、
When heating the normal opening for the time by
“
”
Key to open the heater
,
the
circulation pump will work automatism
。
3)
、
heating thermostat open
,
the furnace is turned on when the thermostat has been circulating
pump rotation
。
4)
、
such as temperature set to 35
℃
,
when the temperature reached or exceeded 36
℃
,
the
heater shut down
,
5 seconds after circulating pump will stop working (cleaning pump did not start the
case)
;
and when the water temperature at or below 34
℃
,
circulating pump restart
,
and re-open the
heater
。
15
、
the operation of blower:
Button
“
”
Control of the wind pump on / off
。
Blower is activated
,
as in the absence of circumstances
,
the work of 20 minutes will be
automatically closed
。
16
、
Fahrenheit and Celsius temperature switch:
In the waiting state by
“
”
Button
,
the temperature in Fahrenheit and Celsius temperature
switch
。
17
、
when the pool water, the three-way water pump and thermostat systems are not
activated, but the LCD display on the corresponding symbol will be flashing.
18
、
Frozen preventing control function
When the water temperature below 5
℃
,
the heater and circulation pump will automatically start
the water heating
,
when the water reached 10
℃
,
the heating stopped
。
This function must ensure that the normal power supply
。
19
、
power control function
(
only of KL8-3H-BAA6
)
There are one power control modes
:
PC1
:
the latter priority
。
Power control all the high-voltage load is divided into two groups
,
one for A
:
circulating
pump
,
and the other group B
:
surf pumps+ blower
。
1), PC1
:
the latter priority mode
:
When opening Group A or B in any one of the load
,
and load a group of self-closing
,
such
as
:
open PUMP1
,
heater and circulating pump shut down automatically
;
the same token
,
open
the heating
,
The surfing pumps and blower shut down automatically
。
2), Setting of power control mode
: