ETHINK KL8-3H Series Programming Instructions Manual Download Page 8

                                                  KL8-3H-CAA6/KL8-3H-BAA6 

www.ethink-spa.com

                                                                  8 

every time

working time is 30 seconds

  ozone work for 15 minutes

15 minutes for clearance

 

        Water surf PUMPS and BLOWER is turned on

ozone can not work

circulating pump is turned 

off

the ozone can not work

 

 

13

  the bottom light steps: 

The first by 

  Key

  to open the underwater lights

the color slowly changes

  the second 

time by 

  The color of the current fixed

  the third time by 

The closure of the 

underwater lights

 

 

14

constant temperature heating steps:   

1), in the pre-heating time to the pre-heating case opened or by 

  Key can be turned on the 

heating system thermostat

 

2

When  heating  the  normal  opening  for  the  time  by 

  Key  to  open  the  heater

the 

circulation pump will work automatism

 

3)

heating thermostat open

  the furnace is turned on when the thermostat has been circulating 

pump rotation

   

4)

such as temperature set to 35 

  when the temperature reached or exceeded 36 

  the 

heater shut down

  5 seconds after circulating pump will stop working (cleaning pump did not start the 

case)

  and when the water temperature at or below 34 

  circulating pump restart

  and re-open the 

heater

   

 

15

the operation of blower: 

Button 

  Control of the wind pump on / off

   

 
Blower  is  activated

as  in  the  absence  of  circumstances

  the  work  of  20  minutes  will  be 

automatically closed

   

 

16

Fahrenheit and Celsius temperature switch: 

In the waiting state by 

  Button

the temperature in Fahrenheit and Celsius temperature 

switch

   

 

17

when  the  pool  water,  the  three-way  water  pump  and  thermostat  systems  are  not 

activated, but the LCD display on the corresponding symbol will be flashing.   
 
18

Frozen preventing control function   

      When the water temperature below 5 

  the heater and circulation pump will automatically start 

the water heating

  when the water reached 10 

  the heating stopped

   

This function must ensure that the normal power supply

   

 

19

power control function

only of KL8-3H-BAA6

   

 There are one power control modes

  PC1

  the latter priority

   

  Power control all the high-voltage load is divided into two groups

one for A

 circulating 

pump

and the other group B

surf pumps+ blower 

 

  1), PC1

  the latter priority mode

   

          When opening Group A or B in any one of the load

and load a group of self-closing

such 

as

  open PUMP1

heater and circulating pump shut down automatically

the same token

open 

the heating

The surfing pumps and blower shut down automatically

   

  2), Setting of power control mode

 

Summary of Contents for KL8-3H Series

Page 1: ...STRUCTIONS 1 key note Figure 1 1 Conventional panel structure Figure 1 3 with TV DVD s DC12V power mask map Frequency up searching Minute The total on off setting confirm Frequency down searching Hour...

Page 2: ...channels 5 87 shows the volume and volume adjustable 6 Long cycle time cycle of cleaning and cleaning function 7 24 hour clock display and setting function 8 With all the settings down memory paramete...

Page 3: ...range 0 59 Set up to wait for 6 seconds after the completion of the system clock set automatically from the state 4 Set up the operation of circulation cleaning Can only be set once a day circulation...

Page 4: ...ire set up process the circulating pump and ozone will not work 5 Pre heat settings Can only be set once a day pre heating Whether or not to start pre heating In the LCD can be at a glance See the fig...

Page 5: ...adjustment range is 0 23 3 Key to switch to the pre heating time for the continuing work of the set state LCD displays the time at least 10 minutes the duration will not be flashing Every time key an...

Page 6: ...automatically shut down pre heating At this point you can also Closed pre heating Note 1 when the temperature is too low less than or equal to the water temperature although the start of pre heating b...

Page 7: ...nd the size of the current volume In the radio turned on the state through and Change the current frequency In the radio to open the state through CLOSE key out of the radio frequency storage Row by C...

Page 8: ...nd re open the heater 15 the operation of blower Button Control of the wind pump on off Blower is activated as in the absence of circumstances the work of 20 minutes will be automatically closed 16 Fa...

Page 9: ...or disconnect B short circuit flow sensor Check the heater and the main electrical box between the cable 5 pin plug or plug is good EP A circulating pump damage B non flow through the internal heater...

Reviews: