ETHINK KL8-3H Series Programming Instructions Manual Download Page 6

                                                  KL8-3H-CAA6/KL8-3H-BAA6 

www.ethink-spa.com

                                                                  6 

15 ~ 42 

 

5

   After all the set and then click 

  Button to confirm

  the system automatically set the 

status from the pre-heating

 

*** Note ***   

  1, pre-heating of all the settings and work must be in the waiting state

   

  2, please refer to LCD is the display 

ON

  or 

OFF

  shows 

ON

”,

  said pre-heating is 

turned on when the pre-heating start working time and the current settings at the same clock

it will 

start pre-heating

Shown as 

OFF

  at any time when it will not start pre-heating

   

          3, set in the entire pre-heating process

  the constant temperature furnace and water pump will 

not start the work cycle

   

 

6

pre-heating of the work:   

  When real-time clock and pre-heating setting start working time consistent

pre-heating is set to 

ON

  and  the  bathtub  with  water

it  will  start  the  pre-heating

circulating  pump  and  automatic 

constant temperature system work at the same time

LCD display position on the countdown clock 

time 

“:

  are no longer flashing

   

  Work in the pre-heating process

when the end of the countdown time

the system automatically 

shut down pre-heating

  At this point you can also 

  Closed pre-heating

 

***Note***

 

1, when the temperature is too low (less than or equal to the water temperature)

although the 

start of pre-heating

but the constant temperature furnace and the circulation pump will not start

 

2, each state (no water

still water

flowing water) switching time of 30 seconds

 

 

7

the work of circulation cleaning:   

  When the real-time clock and the setting start working time of circulation cleaning consistent

 

the circulation cleaning    is set to 

on

the mark

  of LCD panel is on

  and the bathtub 

with water

  it will start the circulation cleaning 

At this point LCD display on the part of the countdown 

time clock

“:

  are no longer flashing

 

  All the surf PUMPS and BLOWER will activate

the working time is 30 seconds

Synchronized to 

start circulating pump

Ozone after 15 minutes of each work will be shut down for 15 minutes

 

In the course of the circulation cleaning

  when the countdown to the end or 

  Key to 

close the cycle of cleaning

 

 

8

on / off operation 

In the waiting state by 

  Key to enter the working state

State in the working state by 

” Can enter the waiting state

LCD display can be seen whether the state boot? 

OFF

                     

OFF

 

Figure 8

waiting state                                  Figure 9

working state 

 

Summary of Contents for KL8-3H Series

Page 1: ...STRUCTIONS 1 key note Figure 1 1 Conventional panel structure Figure 1 3 with TV DVD s DC12V power mask map Frequency up searching Minute The total on off setting confirm Frequency down searching Hour...

Page 2: ...channels 5 87 shows the volume and volume adjustable 6 Long cycle time cycle of cleaning and cleaning function 7 24 hour clock display and setting function 8 With all the settings down memory paramete...

Page 3: ...range 0 59 Set up to wait for 6 seconds after the completion of the system clock set automatically from the state 4 Set up the operation of circulation cleaning Can only be set once a day circulation...

Page 4: ...ire set up process the circulating pump and ozone will not work 5 Pre heat settings Can only be set once a day pre heating Whether or not to start pre heating In the LCD can be at a glance See the fig...

Page 5: ...adjustment range is 0 23 3 Key to switch to the pre heating time for the continuing work of the set state LCD displays the time at least 10 minutes the duration will not be flashing Every time key an...

Page 6: ...automatically shut down pre heating At this point you can also Closed pre heating Note 1 when the temperature is too low less than or equal to the water temperature although the start of pre heating b...

Page 7: ...nd the size of the current volume In the radio turned on the state through and Change the current frequency In the radio to open the state through CLOSE key out of the radio frequency storage Row by C...

Page 8: ...nd re open the heater 15 the operation of blower Button Control of the wind pump on off Blower is activated as in the absence of circumstances the work of 20 minutes will be automatically closed 16 Fa...

Page 9: ...or disconnect B short circuit flow sensor Check the heater and the main electrical box between the cable 5 pin plug or plug is good EP A circulating pump damage B non flow through the internal heater...