background image

                                                                                     

KL8-3A User Manual

 

 

13 

Chemical care 

 
In  order  to  take  care  of  your  spa  investment  and  your  health,  you  must  maintain  correct  chemical 
levels of sanitizer, oxidizer and pH balance. 
Failure to do so may cause damage to equipment  not  covered by warranty, or risk your health. 
 
Correct recommended  ranges are listed below: 
 
Sanitiser – lithium hypochlorite 

 

1.0-3.0 ppm 

pH   

 

 

 

 

 

 

 

7.2-7.8 

Total Alkalinity   

 

 

 

 

80-100 

Calcium Hardness 

 

 

 

 

200-400  

 
We recommend  the use of test strips or digital test strip reader to monitor  your  chemical levels. 
Testing must be carried out twice per week to ensure proper levels. 
We  do  not  recommend  you  rely  on  pool  shop  testing if  carried  out  less  frequently  than  twice  per 
week. 
All  chemical  level  adjustments  made  after  an  initial  test,  require  re-testing  to  ensure  the  level  has 
been corrected.    

 

 

 

 
Please  note  that  we  do  not  recommend  the  use  of  the following  products  / systems  as  damage  to 
equipment  is  far  more  frequent  due  to  the  extremely  high  maintenance  levels  required  and 
neglected. 
Bromine  tablets  –  these  have  a  very  low  pH so are  essentially an  acid  that sanitises  requiring  daily 
monitoring  and adjustments. 
Salt chlorination  – salt remains in solution and is very abrasive to heaters. Chlorine gas is ineffective 
in water over 26 degrees and if there is no ORP control, levels easily exceed maximum levels advised. 
 
We recommend the use of Lithium Hypochlorite as a sanitizer  – its an all-round proven performer at 
moderate pricing, easy to use and low effect on pH. 
 
Our recommended  chemical range: 
Sanitiser: 

 

Lithium Hypochlorite  – granular spa chlorine (do NOT use pool chlorine) 

Oxidiser: 

 

Potassium Mono-persulphate   

pH decreaser: 

Dry acid 

pH increaser: 

Soda Ash 

pH buffer:   

Bi-Carbonate Soda 

 
If  you  are  using  tank  water  you  will  also  need  to  use  a  Hardness  Increaser.  Bore  water  use  may 
require a softener. 
 
If  you  are  allergic  to  Chlorine  an  alternate  chlorine  free  spa  chemical  system  may  need  to  be 
considered. 
We recommend  against the addition of any other spa chemical product  than those listed above. 
 

 

Summary of Contents for KL8-3A

Page 1: ...KL8 3A Installation User Manual...

Page 2: ...t Radio CD input ON OFF Radio volume up Blower ON OFF and Fahrenheit Celsius shift Radio volume down LED light ON OFF Radio channel memory keypad lock Jet pump 1 ON OFF Radio channel searching setting...

Page 3: ...isplay Fig 4 Temperature sensor Fig 5 Temperature display under standby status open short after power on 1 The operation for turning on standby 1 1 When the system is initially powered on the LCD will...

Page 4: ...ally work for 15 seconds and then shut off the circulation pump and ozone will start as well The ozone will work 15 minutes and then cycle off on 5 4 When any jet pump or blower is working the ozone d...

Page 5: ...tration the operation shown as below Each press of key adds 1 hour when the user presses key and holds it the hour will continuously increase The adjustment range is 0 23 3 Press the key to set up the...

Page 6: ...f circulation cleaning Fig 11 the last time is not flashing Each press of key will add 1 hour the longest last time range is 1 19hours 4 Press to confirm all the settings and exit circulation filtrati...

Page 7: ...perature reach or lower than 34 the heater will automatically start again 3 4 When the temperature sensor is open or short LCD will display E1 at this time the heater will not work and temperature is...

Page 8: ...built into the KL8 3A CD AUX when changed from radio to CD AUX 240v power is applied to the AUX socket on the power board for connection of a power supply for a CD player Bluetooth etc Control of the...

Page 9: ...y A6 OFF When the temperature is abnormal or the sensor doesn t detect the water the water pump and heater will stop working ON Not used leave off A7 OFF With water flow sensor if it detects no water...

Page 10: ...irculation Pump AC220V 1HP Blower AC220V 1HP LED Light AC12V 15W 2 wire or DC12V 15W 4 wire Ozone AC12V 8W Radio 1 Frequency range FM87 0 108 0 MHz 2 Max output power 15W 3 Dual channel loud speaker 8...

Page 11: ...8 Wire connection for others Wire colours that may be usedfor cords fittedtooutputs 2 speed pumps Type 1 Type 2 Type 3 LX Davey Low speed Black Black Brown High speed Brown Red Black Neutral Blue Whit...

Page 12: ...KL8 3A User Manual 11...

Page 13: ...ect temperature data will be processed by the spa pack H220 heaters are available in two ratings 1 5kw or 2 0kw They are 1 5 40mm plumbed and suit mid high flow circulation pumps H380 Direction of flo...

Page 14: ...nt is far more frequent due to the extremely high maintenance levels required and neglected Bromine tablets these have a very low pH so are essentially an acid that sanitises requiring daily monitorin...

Page 15: ...d test the electrical circuit and all output devices prior to installing an Ethink KL8 3A control system may result in damage to the unit For example all pumps blower and other 240v output devices mus...