EL2321 Media Converter
25
EL2321 User’s Guide
Revision
: Read-only field that shows the current revision (number of changes) of
Information TLVs. Starting value is zero.
Variable
: Currently not used.
Link Events
: Read-only field that shows whether the device is able to interpret Link
Events.
Loopback
: View-only field that shows whether the device is able to perform loopback.
Unidir
: Read-only field that shows whether the device is able to send OAM PDUs when
the link in the receive path (RX) is not operational. A value of “True” indicates that the
device can send OAM PDUs when the receive path is not operational, while “False”
indicates that it cannot.
Mode
: Read-only field that shows the mode (Active or Passive) of the local and remote
device.
Remote Dying Gasp
Remote Dying Gasp Count
: Indicates the number of unrecoverable failure conditions
that have occurred (e.g. power failure).