EDGe 1
48
0x70 – Low Power Warning:
0x70
Total length Checksum
1 byte
1 byte
1 byte
Command: 0x70
Purpose: A LoRa node is alerting to the network server with low battery power warning.
For example, the packet
“
700272” is composed of
Command byte – 0x70
Total Length – 0x02
Checksum = 0x72