ED3638 www.etherwan.com
Connects power source to ED3638T.
Checks if ED3638R Mode is set to Rmt on DIP switch (Remote, Up position).
Connects power source to ED3638R.
Connects one end of the coaxial cable to BNC interface of the ED3638T and the
other end to BNC interface of the ED3638R.
Data can be transmitted between ED3638T and ED3638R via coaxial cable.
Physical Description
The Port Status LEDs and Power Inputs
ED3638T ED3638R
DC Terminal Block Power Inputs: 2.5A @ 48VDC (Peak current 3.26A).
There are
two pairs of power inputs can be used to power up this Ethernet Extender.
Redundant power supplies function is supported. You only need to have one power
input connected to run the Ethernet Extender.
DC JACK Power input: 2.5A @ 48VDC (Peak current 3.26A).
Power supply suggestion
30 watts application
SDR-120-48 / DR-120-48 (120W 48VDC)
For one pair
SDR-240-48 (240W 48VDC)
For three pairs
SDR-480-48 (480W 48VDC)
For seven pairs
User’s Manual
2