EtherWAN ED3638 Quick Start Manual Download Page 1

ED3638                                                                      www.etherwan.com

 

User’s Manual                                                                                         

1

 

 

Quick Start Guide 

This quick start guide describes how to install and use the Hardened 
Ethernet Extender. This is the Hardened Ethernet Extender of choice for 
harsh environments constrained by space. 

 

Installation 

ED3638T (Transmitter)

: This is a PoL (Power over Link) transmitter. Data and power 

can be delivered at the same time through coaxial cable to turn on and communicate 
with ED3638R (Receiver) via BNC interface. 
 

ED3638R (Receiver):

 This is a PoL (Power over Link) Receiver. ED3638R (Receiver) 

can be powered either by ED3638T (Transmitter) through coaxial cable or power supply. 
The Ethernet port supports IEEE802.3at PoE/PSE for fulfilling PoE/PD application. 
 

<Warning> 

 

Removes the device power before installation. 

 

Removes the device power before any I/O and DIP switch configuration. 

 

Do not connect ED3638T and ED3638R to the same power source. Devices 
may be damaged due to power loop back through the PoL linked via coaxial 
cable. 

 
PoL (Power over Link) Mode Enable Installation 

 

Ensures all power sources are disconnected from ED3638T and ED3638R. 

 

Ensures ED3638T PoL (Power over Link) DIP switch is in 

On

 position (Up position). 

 

Sets ED3638T Type DIP switch to Perf (Performance, Up position) to acquire better 
Line Speed (but poor noise immunity). Or sets Type DIP switch of ED3638T to Std 
(Standard, Down position) to acquire standard Line Speed (but better noise 
immunity). 

 

Checks if ED3638R Mode is set to Rmt on DIP switch (Remote, Up position). 

 

Connects one end of the coaxial cable to BNC interface of the ED3638T and the 
other end to BNC interface of the ED3638R. 

 

Connects power source to ED3638T. 

 

Data and power can be delivered from ED3638T, and at the same time through 
coaxial cable to turn on and communicate with ED3638R. 

 

<Note> 

The equipment is designed for building installation and not intended to be 

connected to exposed (outside plant) networks including campus environment or 
equivalent. 
 
PoL (Power over Link) Mode Disable Installation 

 

For longer distance (e.g. over 1.4km) extension application, ED3638R may not be 
able to receive power from ED3638T. A separate power may be applied on 
ED3638R. 

 

Ensures all power sources are disconnected from ED3638T and ED3638R. 

 

Ensures ED3638T PoL (Power over Link) DIP switch is in

 Off

 position (Down 

position). 

 

Sets ED3638T Type DIP switch to Perf (Performance, Up position) to acquire better 
Line Speed (but poor noise immunity). Or sets Type DIP switch of ED3638T to Std 
(Standard, Down position) to acquire standard Line Speed (but better noise 
immunity). 

Summary of Contents for ED3638

Page 1: ...tion Sets ED3638T Type DIP switch to Perf Performance Up position to acquire better Line Speed but poor noise immunity Or sets Type DIP switch of ED3638T to Std Standard Down position to acquire stand...

Page 2: ...cription The Port Status LEDs and Power Inputs ED3638T ED3638R DC Terminal Block Power Inputs 2 5A 48VDC Peak current 3 26A There are two pairs of power inputs can be used to power up this Ethernet Ex...

Page 3: ...received Power 1 2 3 Off Power off Steady Power Ethernet extension interface function is enabled PoL Off No power is transmitted over Ethernet extension interface Steady Powered device PD is connected...

Page 4: ...0 0W 2400M 4Mbps 30 0W Note The Reference Performance is tested on 5C2V RG6AU Coaxial Cable on a roll type Cable impedance 75ohm 10 100Base TX and Ethernet Extender Connectors 10 100Base TX Connection...

Page 5: ...t Supports Power over Link PoL and provides IEEE802 3at power output up to 500meters 1 640ft and IEEE802 3af power output up to 800meters 2 624ft Supports Power over Ethernet application up to 1 900me...

Page 6: ...tender introduced here provides one channel for Ethernet over existing coaxial cable The Hardened Ethernet Extender fully complies with IEEE802 3 10Base T and IEEE802 3u 100Base TX standards In this m...

Page 7: ...of Contents 7 Introduction 8 Product Overview 8 Product Features 8 Packing List 9 One Channel Hardened Ethernet Extender 10 Ports 10 Ethernet Extender Mode Settings 10 DIP Switch 10 Front Panel LEDs 1...

Page 8: ...638R Product Features Meets EN61000 6 2 EN61000 6 4 EMC Generic Standard Immunity for industrial environment Ethernet port Supports IEEE802 3 802 3u 802 3x Auto negotiation 10 100Mbps full half duplex...

Page 9: ...ax 5W ED3638R Max 35W with PoE output Max 5W without PoE output Power Supply Redundant T 46 57V R 46 57V DC Terminal Block power inputs and 48VDC Latched DC JACK interface Operating temperature range...

Page 10: ...tender Mode Settings Ethernet Extender mode settings are made very simple by means of a DIP Dual Inline Package switch on the top panel of the Hardened Ethernet Extender DIP Switch DIP Switch Down Up...

Page 11: ...g Data transmission or receiving Slow Flashing Extender port under negotiation mode Link Off Extender interface connection is not established Line Speed Steady Displays the link speed in Mbps Steady P...

Page 12: ...le on a roll type Cable impedance 75ohm 10 100Base TX and Ethernet Extender Connectors 10 100Base TX Connection The following lists the pinouts of 10 100Base TX RJ 45 port Pin Regular Port PoE Port 1...

Page 13: ...ould be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the equipment receives adequate ventilation Do not b...

Page 14: ...ED3638 www etherwan com User s Manual 14...

Page 15: ...onnect the DC power cord to the plug able terminal block on the Hardened Ethernet Extender and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut down the Hard...

Page 16: ...ED3638 www etherwan com Power Input Assignment Power1 48VDC DC Jack T 46 57V R 46 57V DC Power2 Power Ground T 46 57V R 46 57V DC Power3 Power Ground Earth Ground Terminal Block User s Manual 16...

Page 17: ...0 80 100 PSE Output Watts 5 15 30 Dimensions 50mm W 110mm D x 135mm H 1 97 W x 4 33 D x 5 31 H Weight 0 77Kg 1 7lbs Power Terminal Block T 46 57V R 46 57V DC DC Jack 48VDC External AC DC required Term...