Etherma ICE-01 Installation And Usage Instructions Download Page 9

 9

DISPOSAL OF PACKAGING

INTENDED USE

The packaging of your high-quality ETHERMA 

product is made from recyclable materials.

•  The frost protection cable for pipelines 

includes an automatic thermostat which on 

the one hand switches on the heating cable 

once it registers a (drop in) temperature to 

approximately 3 °C, and on the other hand 

switches off the heating cable once it regis-

ters a (rise in) temperature to approximately 

9 °C. It is therefore not necessary to check 

the cable.

•  We recommend switching off the heating 

cable in summer (simply unplug it).

•  We recommend inspecting the heating cable 

immediately prior to the cold season and/

or winter for any signs of damage, as well 

as the relevant mains power supply, in order 

to ensure its proper operation, provided that 

the heating cable is not damaged and it is 

ready for operation once it is connected to 

the power supply.

•  The frost protection cable may only be used 

to provide frost protection for metal wa-

ter pipelines with a maximum diameter of 

38 mm.

•  The heating cable must not come into con-

tact with itself, cross or overlap at any point. 

This will cause the cable to overheat.

•  The length of the heating cable must not be 

altered. Shortening the cable poses a risk of 

overheating, while extending it means that it 

will no longer generate the necessary heat. 

Any attempt to physically modify the heating 

cable will void the warranty. Once the heat-

ing cable is damaged, it cannot be repaired.

•  If the heating cable becomes stiff (due to the 

cold weather), first unwind it and plug it into 

a power socket for a couple of minutes until 

it is warm and flexible before installing it on 

the pipeline. Never insert the heating cable 

into the power socket when it is wound up; 

this will cause the cable to overheat at points 

where it comes into contact with itself, and 

melt the outer insulation.

•  Do not install the heating cable on pipelines 

which heat to temperatures exceeding 66 °C, 

such as steam pipes; high temperatures of 

this kind will damage the cable.

• 

To prevent fires, the heating cable must be 

kept at least 13 mm away from any flamma

-

ble material (including flammable insula

-

tion).

•  Never use mineral wool or foam insulation 

more than 13 mm thick. Excessive heating 

cable insulation will lead to overheating. En-

sure that the insulation is fire-resistant.

•  The heating cable must be protected against 

damage (for example by gnawing animals, 

discharge from lawnmowers, snow clearing, 

falling icicles, etc.). 

•  Do not wind the cable; it must remain ex-

tended along the entire length of the pipe.

•  The heating cable must not be immersed in 

liquids.

•  If the mains power cable of the unit is dam-

aged, this must be replaced by the manufac-

turer, a service agent or a similarly qualified 

individual in order to avoid hazards.

Summary of Contents for ICE-01

Page 1: ...schleife mit Thermostat Plug Play heating loop with thermostat Montage und Gebrauchsanleitung Installation and usage instructions Installatie en bedieningsinstructies Instructions d installation et d...

Page 2: ...r in die Steckdose stecken das Ger t nicht regeln das Ger t nicht reinigen und oder nicht die Wartung durchf hren Das Ger t darf nur in montiertem Zustand in Betrieb genommen werden Das Ger t darf nic...

Page 3: ...eder Versuch das Heizkabel physisch zu ver ndern f hrt zum Erl schen der Gew hrleistung Sobald das Heizkabel besch digt wird ist es nicht mehr zu reparieren Wenn das Heizkabel aufgrund der K lte steif...

Page 4: ...und Durchmesser des Rohrs aus W hlen Sie das Kabel das der Rohrausf h rung am n chsten kommt Das Kabel darf nicht mehr als 600 mm k rzer als das Rohr und nicht l nger als das Rohr sein Es be steht die...

Page 5: ...Heizkabel hieran angeschlossen werden kann Formen Sie eine Tropfschleife in das Netzkabel um zu verhindern dass etwaiges Kondenswasser der Leitung in die Steckdose gelangt F r den Fall dass ein Verl n...

Page 6: ...der Bereich rund um das Thermostat nicht so gut isoliert ist wie andere Bereiche der Leitung schaltet das Thermostat die Kabel auf einen un konomischen Betrieb Das Thermostat schaltet die Heizkabel ei...

Page 7: ...ertvolle Materialien Sie k nnen aber auch sch dliche Stoffe enthalten die f r Ihre Funktion und Sicherheit notwendig waren Im Restm ll oder bei falscher Behandlung k nnen diese der Umwelt schaden Bitt...

Page 8: ...e clean it and or carry out maintenance The device may only be operated once in stalled The device may not be used in small rooms occupied by persons who cannot leave the room independently except whe...

Page 9: ...o longer generate the necessary heat Any attempt to physically modify the heating cable will void the warranty Once the heat ing cable is damaged it cannot be repaired If the heating cable becomes sti...

Page 10: ...the pipe Select the insulation to be fitted over the heating cable pipe The insulation can be up to a maximum of 13 mm thick Either foam or mineral wool insulation can be used Ensure that the foam in...

Page 11: ...be insulated with mineral wool or flexible plastic foam insulation THE INSULATION MUST BE FITTED EVENLY TO THE THERMOSTAT AS WELL AS TO THE PIPE HEATING CABLE in order to ensure that all parts of the...

Page 12: ...contain valuable materials However they can also contain harmful substances which were required for their operation and safety Such substances may damage the environment if disposed of in residual wa...

Page 13: ...ken het apparaat niet regelen het apparaat niet schoonmaken en of het onderhoud uitvoe ren Het apparaat mag alleen in gemonteerde vorm in gebruik worden genomen Het apparaat mag niet gebruikt worden i...

Page 14: ...poging om de ver warmingskabel fysiek aan te passen vervalt de garantie Zodra de verwarmingskabel is beschadigd is hij niet meer te repareren Is de verwarmingskabel als gevolg van de kou stijf dan moe...

Page 15: ...lde kant van de buis worden geplaatst Kies de isolatie die over de verwarmings kabel buis moet worden aangebracht De isolatie mag niet meer dan 13 mm dik zijn Er kan zowel isolatie met schuim als mine...

Page 16: ...flexibele kunststof schuimisolatie DE ISOLATIE MOET OP PRECIES DEZELFDE WIJZE OP DE THERMOSTAAT WORDEN AANGE BRACHT ALS OP DE VERWARMINGSKABEL VAN DE LEIDING om er zeker voor te zorgen dat alle delen...

Page 17: ...stoffen bevatten die noodzakelijk waren voor hun functioneren en veiligheid Komen deze laatste bij het restafval terecht of worden ze verkeerd verwerkt dan kun nen ze het milieu schaden Help ons alstu...

Page 18: ...l appa reil nettoyer l appareil et ou effectuer une maintenance L appareil doit tre uniquement mis en ser vice dans son tat mont L appareil ne doit pas tre utilis dans les petites pi ces occup es par...

Page 19: ...tentative de modification physique du c ble chauffant entra ne la d ch ance de la garan tie Si le c ble chauffant est endommag il ne peut plus tre r par Si le c ble chauffant est rigide en raison du...

Page 20: ...ournevis Mesurez la longueur et le diam tre du tuyau S lectionnez le c ble s approchant au mieux de l ex cution du tuyau Le c ble ne doit pas mesurer plus de 600 mm de moins que le tuyau ni tre plus l...

Page 21: ...cher le c ble chauffant Formez une boucle d gouttement dans le cordon d alimenta tion pour viter qu une condensation ven tuelle de la conduite ne p n tre dans la prise Pour le cas o une rallonge est n...

Page 22: ...tour du thermostat n est pas aussi bien isol e que les autres zones de la conduite le thermostat allume le c ble dans un mode non conomique Le thermostat allume les c bles chauffants s il enregistre d...

Page 23: ...substances nocives qui taient n cessaires leur fonctionnement et leur s curit Dans les d chets m nagers ou en cas de mauvaise manipu lation elles peuvent polluer l environnement Veuillez aider la pro...

Page 24: ...ETHERMA Elektrow rme GmbH Landesstra e 16 A 5302 Henndorf Tel 43 0 6214 76 77 Fax 43 0 6214 76 66 Web www etherma com Mail office etherma com...

Reviews: