Etesia PA362E User Manual Download Page 8

8

Most operating problems are due to wrong handling and using, poor use of the rechargeable storage cell or the lack of normal recommended 

maintenance.
The following table describes simple methods of determining a few malfunctions and correcting them.
If the problem persists, we recommend that you contact one of our approved ETESIA dealers (list on requist to ETESIA - 67165 

WISSEMBOURG Cedex - France).

ANORMAL OPERATION

 

PROBABLE CAUSE

 

REMEDY

The voltage indicator of the charger  Default charger power ....................................................Unplug the power cord and verify its good 

does not turn on. 

                                                                                        condition and make sure the outlet is turned on.

The LEDs of the display will not 

Default on the charging circuit of the storage ................Installing or replacing the fuse «F15A». 

turn on and charge indicator  

cell (fuse «F15A» of the rechargeable storage 

remains off when the charger is 

cell is missing or defective). 

turned on. 

The charge indicator is green, but 

The charge was interrupted because of ..........................Unplug the charger and let it cool, then  

the 5 lights on the charge status 

overheating of the rechargeable storage cell.                  reconnect to resume charging. 

display of the storage cell are not 

 

all on.

The charge indicator is red, and the 

The charge was interrupted because of ..........................Unplug the charger and let it cool, then  

lights on the charge status display 

overheating of the charger and the rechargeable            re-connect to resume charging. 

of the storage cell are all off. 

storage cell is automatically put on standby.

Important:

 Only use ETESIA parts as replacements. The quality of the work, the life of the rechargeable storage cell and 

your safety depend on it.

In addition to risks incurred by the user, the use of parts other than the manufacturer’s will result in the cancellation of the warranty for any 
damage caused. ETESIA refuse to accept responsibility for accidents due to the use of parts not coming from the manufacturer.

9• STANDARD REPAIRS - PROBLEMS AND REMEDIES

8• WINTER STORAGE - LONG STOP

Do not store your rechargeable storage cell fully charged or 

discharged for a long time. Doing so may cause permanent 

damage.

- After the last use before storage period, recharge the storage cell to 

half (3 lights on the charge status display, no green LED on).

- Before reusing the storage cell after a period of no use of about 6 

months, simply do a full recharge of the storage cell.

If the period without use should extend beyond the normal period of 

winter storage, maintenance operation would be necessary:

Fully discharge the storage cell after the first 6 months of storage, 

then recharge it to half (3 lights on the charge status display, no 

green LED on).

- Repeat this maintenance every 6 months if the period without use 

should extends beyond 12 months.

Summary of Contents for PA362E

Page 1: ...PA362E GB User Manual Translation of the originals instructions manual Please read carefully before using your rechargeable storage cell RECHARGEABLE STORAGE CELL N ERGY LI ION 36 V 21 AH...

Page 2: ...ion 5 4 Pictures 6 5 Technical specifications 6 6 Preparation and getting started 7 7 Maintenance 7 8 Winter storage Long stop 8 9 Standard repairs Problems and remedies 8 10 Protection of the Environ...

Page 3: ...tery for their intended application u If possible remove the battery from the device when not in use v Properly dispose SAFETY PRECAUTIONS N ERGY PA362E rechargeable storage cell should not be exposed...

Page 4: ...recharged with the CA362E charger separately available CA362E charger has many automatic features and has been specially designed for recharging in complete safely CA362E charger should only be used...

Page 5: ...ivation and standby button 4 Charging socket 5 Fuses 1 Before using please read and follow the safety and maintenance instructions included in the manual 2 Do not expose to rain 3 Do not directly sold...

Page 6: ...RES Model PA362E Version N ERGY Li Ion ref 50030 36 V 21 Ah 756 Wh Load circuit protection by F15 fuse Discharge circuit protection by T30 fuse Dimensions 410 mm x 274 mm x 190 mm Weight 6 5 kg 5 TECH...

Page 7: ...storage cell informs you about the progress of the charging 5 coloured LEDs light up progressively starting with the red light next to the I O button When the five lights are on the rechargeable stora...

Page 8: ...it cool then lights on the charge status display overheating of the charger and the rechargeable re connect to resume charging of the storage cell are all off storage cell is automatically put on stan...

Page 9: ...with unsorted municipal waste and to collect them selectively through recovery and collection systems available to them Batteries contain hazardous materials and should not be released into the natura...

Page 10: ...be paid back to the dealer according to charge scale mentioned in the agreement Every capacity loss exceeding 30 of the initial capacity of the rechargeable N ERGY PA362E storage cell provided that it...

Page 11: ...one mentioned in the ETESIA dealership IMPORTANT NOTE As soon as a machine purchase takes place the warranty cards needs to be completed signed and sent back to ETESIA SERVICE GARANTIE 67165 WISSEMBOU...

Page 12: ...11 65 UE Restrictions on the use of hazardous substances in electrical and electronic equipment Mr Claude Treger 13 rue de l industrie 67165 Wissembourg CEDEX is the person authorized to constitute th...

Page 13: ...ETESIA SERVICE GARANTIE 13 rue de l Industrie 67165 WISSEMBOURG CEDEX France Stamp here please...

Page 14: ...ture____________________ Signature and confirmation of the user that he has taken possession of a machine in perfect working order that the user has been handed over and that he thoroughly read the us...