![Etesia PA362E User Manual Download Page 8](http://html1.mh-extra.com/html/etesia/pa362e/pa362e_user-manual_2432498008.webp)
8
Most operating problems are due to wrong handling and using, poor use of the rechargeable storage cell or the lack of normal recommended
maintenance.
The following table describes simple methods of determining a few malfunctions and correcting them.
If the problem persists, we recommend that you contact one of our approved ETESIA dealers (list on requist to ETESIA - 67165
WISSEMBOURG Cedex - France).
ANORMAL OPERATION
PROBABLE CAUSE
REMEDY
The voltage indicator of the charger Default charger power ....................................................Unplug the power cord and verify its good
does not turn on.
condition and make sure the outlet is turned on.
The LEDs of the display will not
Default on the charging circuit of the storage ................Installing or replacing the fuse «F15A».
turn on and charge indicator
cell (fuse «F15A» of the rechargeable storage
remains off when the charger is
cell is missing or defective).
turned on.
The charge indicator is green, but
The charge was interrupted because of ..........................Unplug the charger and let it cool, then
the 5 lights on the charge status
overheating of the rechargeable storage cell. reconnect to resume charging.
display of the storage cell are not
all on.
The charge indicator is red, and the
The charge was interrupted because of ..........................Unplug the charger and let it cool, then
lights on the charge status display
overheating of the charger and the rechargeable re-connect to resume charging.
of the storage cell are all off.
storage cell is automatically put on standby.
Important:
Only use ETESIA parts as replacements. The quality of the work, the life of the rechargeable storage cell and
your safety depend on it.
In addition to risks incurred by the user, the use of parts other than the manufacturer’s will result in the cancellation of the warranty for any
damage caused. ETESIA refuse to accept responsibility for accidents due to the use of parts not coming from the manufacturer.
9• STANDARD REPAIRS - PROBLEMS AND REMEDIES
8• WINTER STORAGE - LONG STOP
Do not store your rechargeable storage cell fully charged or
discharged for a long time. Doing so may cause permanent
damage.
- After the last use before storage period, recharge the storage cell to
half (3 lights on the charge status display, no green LED on).
- Before reusing the storage cell after a period of no use of about 6
months, simply do a full recharge of the storage cell.
If the period without use should extend beyond the normal period of
winter storage, maintenance operation would be necessary:
-
Fully discharge the storage cell after the first 6 months of storage,
then recharge it to half (3 lights on the charge status display, no
green LED on).
- Repeat this maintenance every 6 months if the period without use
should extends beyond 12 months.