PREPARATION OF THE
RECHARGEABLE STORAGE CELL
For safety reasons during transport, the protective fuses of
your rechargeable storage cell are not installed on delivery
.
• Turn the rechargeable storage cell, unscrew and remove the lids of
the two fuse holders marked «T30A» and «F15A» (see picure 1).
• Install the 2 fuses supplied with your rechargeable storage cell and
screw the lids back.
CHARGING THE RECHARGEABLE
STORAGE CELL
WARNING!
N-ERGY PA362E rechargeable
storage cell must only be recharged with the
CA362E charger. Recharging should not be done in
confined areas or an environment which is damp,
dusty or under exposure to heat.
CONNECTING THE CA362E CHARGER
• Remove the protective cap from the charging socket of the
rechargeable storage cell and connect the charging cable connector
(see 1 picture 2) respecting the orientation determined by the
actuator and screw and tighten the retaining ring.
• Connect the plug of the power cord to a 230 V~ power outlet.
It automatically activates the charging status display on top of the
rechargeable storage cell (see 2 picture 2) which is accompanied by
the LEDs on the front of the charger being lit.
-
Voltage indicator lit red (see 3 picture 2) : The charger is
powered correctly.
-
Charging indicator lit red (see 4 picture 2) : Charge cycle in
progress.
Monitoring the charge cycle and charge termination
The observation of the charging status display on top of the
rechargeable storage cell informs you about the progress of the
charging. 5 coloured LEDs light up progressively, starting with the
red light next to the «I/O» button.
When the five lights are on, the rechargeable storage cell is almost
charged. When charging is complete, the charging current is
automatically terminated and the charge indicator on the charger
changes colour (green).
• Remove the power cord plug from the 230 V outlet.
• Unscrew the retaining ring and remove the charging connector.
• Put on the protective cap on the input socket of the rechargeable
storage cell.
• Put the rechargeable storage cell in stand-by mode by pressing the
«I/O» button on the display: the lights go out.
Otherwise, the rechargeable storage cell is put on stand-by by itself
after a few minutes.
6• PREPARATION AND GETTING STARTED
7• MAINTENANCE
ROUTINE MAINTENANCE OF THE
RECHARGEABLE STORAGE CELL
Rechargeable N-ERGY PA362E storage cell only requires a few
precautions and maintenance. However, it is sensitive to shocks,
abnormal heating, humidity and dust.
You should take care of:
- Ensuring regular cleaning with a dry rag without water.
- Ensuring its connectors are clean using a non-metallic soft brush.
- Making sure not to expose it to shock, heat, moisture and dust.
- Carrying out the scheduled maintenance work for prolonged period
without use.
- Storing it in a dry, well-ventilated place at a temperature between
-20 °C and +50 °C. Storage at a temperature outside this range
could damage the storage cell.
You never have to dismantle your rechargeable
N-ERGY PA362E storage cell to intervene yourself.
In case of problems, contact a ETESIA-qualified
specialist.