Warning
To avoid false readings, which could lead to possible electric shock or
personal injur y, replace the battery as soon as the battery indicator “ ”
appears.
Make sure the transformer jaw and the tets leads are disconected from the
circuit being tested before opening the case bottom.
To replace the battery:
1. Turn the Meter off and remove all the connections
from the input terminals
2. Turn the Meter’s case top down.
3. Remove the screw from the battery compartment, and separate the battery
compartment from the case bottom.
4. Remove the old battery from the battery compartment.
5. Replace the battery with 2pcs of new 1.5V (AAA)
battery.
6. Rejoin the case bottom and the battery compartment,
and reinstall the screw.
- 14 -
( Figure 9)
Screw
Warning
A. General Service
B. Replacing the Battery
(See Figure 9 )
Do not attempt to repair or service your Meter unless
you are qualified to do so and have the relevant
calibration, performance test, and service information.
To avoid electrical shock or damage to the Meter, do
not get water inside the case.
Periodically wipe the case with a damp cloth and mild
detergent. Do not use abrasives or solvents.
To clean the terminals with cotton bar with detergent,
as dirt or moisture in the terminals can affect readings.
Turn the Meter power off when it is not in use.
Take out the battery when it is not using for a long time.
Do not use or store the Meter in a place of humidity,
high temperature, explosive, inflammable and strong
magnetic field.
Summary of Contents for MSR-C600
Page 1: ...User Manual Digital Clamp Multimeter model no MSR C600 ...
Page 3: ... 2 Warning range ...
Page 12: ... 11 Low Battery Indication Display 6 1 Specifications Opening Tested H 2 ...
Page 13: ... 12 3 Display sinewave RMS AVG response ...
Page 16: ...Questions or Concerns support etekcity com visit etekcity com for more products ...