16
Note:
• If the temperature probe is not attached, the
display will show “
” when this function is
selected.
• The included type K (NiCr–NiSi) thermocouple
can
only
be used for temperatures lower than
482°F (250°C), or the thermocouple will be
damaged. Use a different thermocouple for
higher temperatures.
Temperature Measurement
1.
Turn the rotary dial to the temperature
(
°F
°C
) position. Press
SELECT
to choose
Fahrenheit or Celsius units. [
Figure 8.1
]
2. Use the type K thermocouple temperature
probe. Insert the
black test lead
into the
COM
terminal, and the
red test lead
into
the
terminal.
3. Connect the probe on the object being
measured. Hold them in place until the
reading on the display stabilizes.
Note:
• The measurement range is 10Hz–10MHz.
• The measurement signal should be less than
30V, or measurement accuracy may be affected.
Frequency Measurement
1.
Turn the rotary dial to the
Hz
position.
[
Figure 9.1
]
2. Insert the
black test lead
into the
COM
terminal, and the
red test lead
into the
terminal.
3. Connect the test leads in parallel to the
signal source. Hold them in place until the
reading on the display stabilizes.
Hz
A
mA
µA
mV
V
V
OFF
NCV
Ω
°F°C
Hz
A
mA
µA
mV
V
V
OFF
NCV
Ω
°F
°C
Figure 9.1
Figure 8.1
SELECT